Dimensions of Countertop Cutout
Side View with an Oven
Min. 60
Min. 5
Min. 40
Flow of intake
and exhaust
Oven
When Installing Above an Oven
■
The appliance may only be installed over a Panasonic oven.
■
Allow for extra spaces for air circulation as shown below.
Dimensions
(measurement: mm)
R3 1
490
3 0
870
3
0
Building side wall
Countertop front
Min. 59
Building side wall
Building rear wall
Min.51
Min.600
Min.51
Min.51
Min. 60
Min. 5
Min. 40
Oven
Electrical Work
WARNING
Electrical work must be performed by a legally qualified electrician.
Electrical Requirements
Installation of the Earth Leakage Circuit Breaker
■
This appliance must be supplied with the proper voltage and frequency, and
connected to an individual, properly earthed branch circuit, protected by a
circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)
■
This appliance is not fitted with other means for disconnection from the supply
mains having a contact separation in all poles that provide full disconnection
under overvoltage category III conditions. Means for disconnection must be
incorporated in the fixed wiring in accordance with the wiring rules.
■
Single-phase A.C. 220-240 V, 50 Hz electrical system must be used. (It is also
possible to use a three-phase electrical system.) If connecting to aluminium
wiring, use connectors approved for use with aluminium wiring.
■
Check with the local utilities for electrical codes applied in the area. Failure to
wire the appliance according to governing codes may result in a hazardous
condition.
■
After installation, show the customer where the breaker for the appliance is
located.
■
In accordance with the electrical wiring rules, incorporate the earth leakage
circuit breaker in the home electrical wire.
■
Follow the specification of the earth leakage circuit breaker as follows.
Rated current: 50 A*, rated sensitivity current: 30 mA
* If rated current is 40 A, please change to 7200 W under “Power Management”
in settings.