2.6 Hardware (H/W) Settings
148
Programming Guide
VOX Undetected Length
Specifies the length of time to detect VOX. If VOX is not detected within the specified time, the call
will be recognised as end when the VOX detection is recognised as status of call.
Value Range
1000 ms–60000 ms, Units 500 ms
AGC
Enables or disables AGC (Automatic Gain Control).
Value Range
Disable, Enable
AGC Optimum Level
Specifies the optimum level for AGC.
Value Range
-245–10 dBm
AGC Minimum Level
Specifies the minimum level for AGC.
Value Range
-245–10 dBm
AGC Attack Time
Specifies AGC attack time.
Value Range
0 ms–1275 ms, Units 5ms
AGC Decay Time
Specifies AGC decay time.
Value Range
50 ms–500 ms, Units 50 ms
500 ms–25000 ms, Units 100 ms