11.6. Things to Do after Replacing IC
Cautions:
Since this page is common to each country, it may not apply to some models in your country. The contents below are the mini-
mum adjustments required for operation.
11.6.1. Base Unit
Before doing the following adjustment, be sure to do
PC Setting
(P.47) in
The Setting Method of JIG (Base Unit)
.
Note:
(*1) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in
JIG and PC
(P.47).
(*2) Refer to
Check Point (Base Unit)
(P.34)
11.6.2. Handset
Before doing the following adjustment, be sure to do
PC Setting
(P.48) in
The Setting Method of JIG (Handset)
.
Note:
(*3) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in
JIG and PC
(P.47).
(*4) Refer to
Check Point (Handset)
(P.38)
IC
Necessary Adjustment
BBIC
(IC7)
Programs for Voice processing, interface for RF and
EEPROM
1. Default batch file: Execute the command “default.bat”.
2. Country version batch file: Execute the command
“TG7100XXrevYY.bat”. (*1)
3. Clock adjustment: Refer to Check Point (F). (*2)
EEPROM
(IC5)
Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Change the address “0000” of EEPROM to “00”.
2. Default batch file: Execute the command “default.bat”.
3. Country version batch file: Execute the command
“TG7100XXrevYY.bat”. (*1)
4. Clock adjustment: Refer to Check Point (F). (*2)
IC
Necessary Adjustment
BBIC
(IC1)
Programs for Voice processing, interface for RF and
EEPROM
1. Default batch file: Execute the command “default.bat”.
2. Default batch file (remaining); Execute the command
“TGA710 DEFrevYY.bat”. (*3)
3. Country version batch file: Execute the command
“TGA710XXrevYY”. (*3)
4. Clock adjustment: Refer to Check Point (J). (*4)
5. 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4)
EEPROM
(IC3)
Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Change the address “0015” of EEPROM to “00”.
2. Default batch file: Execute the command “default.bat”.
3. Default batch file (remaining); Execute the command
“TGA710 DEFrevYY.bat”. (*3)
4. Country version batch file: Execute the command
“TGA710XXrevYY”. (*3)
5. Clock adjustment: Refer to Check Point (J). (*4)
6. 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4)
Содержание KX-TG7100ES
Страница 2: ...2 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES ...
Страница 14: ...14 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 4 6 Signal Route ...
Страница 20: ...20 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 7 4 For Service Hint ...
Страница 21: ...21 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Страница 23: ...23 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 8 1 2 Handset ...
Страница 29: ...29 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES Cross Reference Check Point Base Unit P 34 ...
Страница 31: ...31 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES Cross Reference Check Point Handset P 38 ...
Страница 44: ...44 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 10 1 2 Handset ...
Страница 45: ...45 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 10 1 3 Charger Unit ...
Страница 46: ...46 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 10 2 How to Replace the Handset LCD ...
Страница 75: ...75 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 15 3 Cabinet and Electric Parts Charger Unit ...
Страница 76: ...76 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 15 4 Accessories and Packing Materials 15 4 1 KX TG7100ES ...
Страница 77: ...77 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 15 4 2 KX TG7102ES ...