35
KX-TG7100ES/KX-TG7102ES/KX-TG7103ES/KX-TGA710ES
(
G
)* Hookswitch Check with
DC Characteristics
-
1. Connect CN1 (Telephone Socket) to Tel-simulator which is connected with
600
Ω
.
2. Set line voltage to 48 V and line current to 40mA at off-hook condition of nor-
mal telephone.
3. Execute the command “hookoff”
4. Confirm that the line current is 40 mA ± 5 mA.
5. Execute the command “hookon”.
6. Confirm that the line current is less than + 0.8 mA.
L1, L2, Q3, R14,
R15, Q4, R16,
R17, IC7, D3
(
H
)* DTMF Generator Check
-
1. Connect CN1 (Telephone Socket) to DTMF tester. (Road=600
Ω
)
2. Link Handset and push dial key.
3. Confirm DTMF character.
4. Confirm that the high Group is -6.0 dBm ~ -10.0 dBm.
5. Confirm that the low Group is -8.5 dBm ~ -12.5 dBm.
IC7, R67, IC6,
R116, C141,
R29, C22, C23,
R18~R24,
C14~C17, Q5,
D4
(
I
)* Transmitted Power Con-
firmation
-
Remove the Antenna before starting step from 1 to 7.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Short A_1 and GND.
• Test mode: FP
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70dBm.
2. Execute the command “testmode”.
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
RFPI”.
5. Initiate connection from Dect tester (“set up connect”)
6. Execute the command “ANT1”.
7. Confirm that the NTP value at ANT is 20 dBm ~ 25 dBm.
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(
J
)
Modulation Check and
Adjustment
-
Follow steps 1 to 6 of
(I)
.
7.Confirm that the B-Field Modulation is -350 ~ -400/+320 ~ +370 kHz/div using
data type Fig31.
8.Adjust the B-Field Modulation if required. (Execute the command “readmod”
and “wrtmod xx”, where xx is the value.)
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(
K
) Frequency Offset Check
-
Follow steps 1 to 6 of
(I)
.
7.Confirm that the frequency offset is < ± 45 kHz.
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(
L
)
Frequency Dirft Confir-
mation
-
Follow steps 1 to 6 of
(I)
.
7.Confirm that the frequency drift is < ± 30 kHz/ms.
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
Items
Check
Point
Procedure
Check or
Replace Parts
Содержание KX-TG7100ES
Страница 2: ...2 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES ...
Страница 14: ...14 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 4 6 Signal Route ...
Страница 20: ...20 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 7 4 For Service Hint ...
Страница 21: ...21 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Страница 23: ...23 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 8 1 2 Handset ...
Страница 29: ...29 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES Cross Reference Check Point Base Unit P 34 ...
Страница 31: ...31 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES Cross Reference Check Point Handset P 38 ...
Страница 44: ...44 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 10 1 2 Handset ...
Страница 45: ...45 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 10 1 3 Charger Unit ...
Страница 46: ...46 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 10 2 How to Replace the Handset LCD ...
Страница 75: ...75 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 15 3 Cabinet and Electric Parts Charger Unit ...
Страница 76: ...76 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 15 4 Accessories and Packing Materials 15 4 1 KX TG7100ES ...
Страница 77: ...77 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 15 4 2 KX TG7102ES ...
Страница 78: ...78 KX TG7100ES KX TG7102ES KX TG7103ES KX TGA710ES 15 4 3 KX TG7103ES ...