40
KX-TG6511RU/KX-TG6512RU/KX-TGA650RU/KX-TGA651RU
(
F
)* Battery Monitor Check
-
1. Apply 2.25 V between BATT+ and BATT-.
2. Execute the command
sendchar PAD
sendchar LED 0
sendchar CRX 0 1
sendchar AD1
It assumes that the return value is XX.
a) 6c XX 71: No need to adjust
b) XX: 6A ~ 6B: Need to adjust
XX: 72 ~ 74: Need to adjust
Write AD value of 2.25 V to EEPROM.
ex) read data: XX = 6A, write data: YY = 6A
read data: XX = 73, write data: YY = 73
EEPROM = 0004(Low Voltage) write “YY”
Execute the command “wreeprom 00 04 01 YY”.
EEPROM = 0005(No Voltage) write ‘’YY - 1D’’
Execute the command “×wreeprom 00 05 01 ZZ”.
EEPROM = 000A(Low Voltage BL) write “YY - 16”
Execute the command “wreeprom 00 0A 01 WW”.
Note:
ZZ = YY - C
No Voltage writing data limit is ‘00’.
c) XX: 00 ~ 69: Reject
XX: 75 ~ FF: Reject
IC1, F1, C1,
R45
(
G
)
Battery Low Confirma-
tion
-
1. Apply 2.40 V between BATT+ and BATT-.
2. Confirm that there is no flashing of Battery Icon.
3. Apply 2.25 V ± 0.08 V between BATT+ and BATT-.
4. Confirm that there is flashing of Battery Icon.
IC1, F1, C1,
R45
(
H
)* BBIC Clock Adjustment
CLK
1. Apply 2.6 V between BATT+ and BATT- with DC power.
2. Input Command “sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CLK exe-
cuting the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
Clear the registered information for Base Unit before measurement, because the
Frequency will not possibly get stable due to the registered information.
Pressing the button of “3” “7” “9” “#” clears the registration.
Register to it on Base Unit after measurement.
IC1, X1, C47
(
I
)* Transmitted Power Con-
firmation
-
Remove the Antenna before starting step from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
2. Execute the command “sendchar TST 01 02 03 04 05".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 25 dBm.
IC1,
C802~C806,
C808~C814,
C819~C820,
C822,
C825~C827,
C834,
C860~C864,
L801~L804,
DA801,
R801~R808
(
J
)* Modulation Check and
Adjustment
-
Follow steps 1 to 3 of
(K)
.
4.Confirm that the B-Field Modulation is -370±30/ +370±30 kHz/div & Modulated
width 690 kHz using data type Fig 31.
IC1,
C802~C806,
C808~C814,
C819~C820,
C822,
C825~C827,
C834,
C860~C864,
L801~L804,
DA801,
R801~R808
Items
Check
Point
Procedure
Check or
Replace Parts
Содержание KX-TG6511RUB
Страница 2: ...2 KX TG6511RU KX TG6512RU KX TGA650RU KX TGA651RU ...
Страница 14: ...14 KX TG6511RU KX TG6512RU KX TGA650RU KX TGA651RU 4 6 Signal Route ...
Страница 16: ...16 KX TG6511RU KX TG6512RU KX TGA650RU KX TGA651RU 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Страница 18: ...18 KX TG6511RU KX TG6512RU KX TGA650RU KX TGA651RU 8 1 2 Handset ...
Страница 27: ...27 KX TG6511RU KX TG6512RU KX TGA650RU KX TGA651RU Cross Reference Check Point Base Unit P 35 ...
Страница 29: ...29 KX TG6511RU KX TG6512RU KX TGA650RU KX TGA651RU Cross Reference Check Point Handset P 39 ...
Страница 44: ...44 KX TG6511RU KX TG6512RU KX TGA650RU KX TGA651RU 10 1 2 Handset ...
Страница 45: ...45 KX TG6511RU KX TG6512RU KX TGA650RU KX TGA651RU 10 1 3 Charger Unit ...
Страница 76: ...76 KX TG6511RU KX TG6512RU KX TGA650RU KX TGA651RU 15 3 Cabinet and Electrical Parts Charger Unit ...
Страница 77: ...77 KX TG6511RU KX TG6512RU KX TGA650RU KX TGA651RU 15 4 Accessories ...