![Panasonic KX-TDE600 Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/panasonic/kx-tde600/kx-tde600_installation-manual_258035040.webp)
Note for KX-NT265 IP-PT users
The supported card varies depending on the software version of your KX-NT265 IP-PT. To confirm the version,
follow the procedure below:
"
AP Version
".
Select
"Maintenance".
Software version
is displayed.
While starting up
Select
"Version display".
To exit the programming mode
PROGRAM
SP-PHONE
SP-PHONE
SP-PHONE
HOLD
HOLD
HOLD
HOLD
Power Supply Unit Selection for Each Shelf
The PBX needs a power supply unit (PSU) suitable for its configuration. For each shelf, calculate the load
figure from the type and number of items of equipment to be connected, and then determine the type of PSU
that will be required.
Note
Regardless of the total load figure, if a shelf contains an ECSLC24 card, the PSU-L must be installed.
Load Figure Calculation
Equipment Type
Load Figure
PT
KX-DT300 series DPT/KX-DT300 series DSS
console/KX-T7600 series DPT/KX-T7600 series
DSS console
1
KX-T7560/KX-T7565 DPT
1
Other DPT/Other DSS console
4
APT
4
IP-PT
0
SIP Extension
0
Extension Card
*1
DHLC8
8
SLC8
8
ESLC16/CSLC16/EMSLC16
16
ECSLC24
24
CS (1 unit)
4
High-density CS (1 unit)
8
IP-CS (1 unit)
0
ISDN Extension
2
40
Installation Manual
1.3.3 System Capacity
Содержание KX-TDE600
Страница 42: ...42 Installation Manual 1 3 3 System Capacity ...
Страница 249: ...Section 6 Appendix Installation Manual 249 ...
Страница 251: ...Index Installation Manual 251 ...
Страница 257: ...Installation Manual 257 Notes ...