Power Supply Unit Selection
The PBX needs a power supply unit (PSU) suitable for its configuration. Calculate the load figure from the type
and number of items of equipment to be connected, and determine the type of PSU that will be required.
Load Figure Calculation
Equipment Type
Load Figure
PT
KX-DT300 series DPT/KX-DT300 series DSS
console/KX-T7600 series DPT/KX-T7600 series
DSS console
1
KX-T7560/KX-T7565 DPT
1
Other DPT/Other DSS console
4
APT
4
IP-PT
0
SIP Extension
0
Extension Card
DHLC8
8
SLC8
8
SLC16/MSLC16/CSLC16
16
CS (1 unit)
4
High-density CS (1 unit)
8
IP-CS (1 unit)
0
ISDN Extension
2
VPS (1 port)
1
*1
Only the extension cards that can support SLTs count for the load figures.
Installation Manual
37
1.3.3 System Capacity