1.4 D
Feature Manual
65
1.4
D
1.4.1
Data Line Security
Description
Once Data Line Security is set on an extension, communication between the extension and the other party
is protected from signals such as Call Waiting, Hold Recall and Executive Busy Override. Extensions which
have devices connected to them such as modems or fax machines may set this feature to maintain secure
data transmission, by blocking tones or other interruptions during communication.
Programming References
PC Programming Manual
2.9.8 [2-6-1] Numbering Plan—Main—Features—Data Line Security Set / Cancel
2.11.1 [4-1-1] Wired Extension—Extension Settings—Option 2—Data Mode
PT Programming Manual
None
Operating Manual References
1.3.17 Data Line Security
1.4.2
Dial Mode Selection
Description
The dialing mode (rotary or tone) can be selected for each analog CO line through system programming
regardless of the originating extension (under contract with the telephone company).
Conditions
•
Pulse to Tone Conversion
It is possible for an extension user to temporarily switch from Pulse mode to DTMF mode in order to
access special services such as computer-accessed long distance calling or voice mail services. To
switch to DTMF mode, wait for a preprogrammed time period (Default: 5 seconds) after the CO line is
connected, or press . This feature works only on CO lines set to Pulse mode. DTMF mode cannot be
changed to Pulse mode.
•
It is possible to select a pulse rate for the CO line port which has been set to Pulse mode. There are
two pulse rates: Low (10 pps) and High (20 pps).
Mode
Description
DTMF (Dual Tone Multi-
Frequency)
Numbers dialed by an extension user are transmitted to the CO line
using analog tones.
Pulse Dial (Rotary)
Numbers dialed by an extension user are transmitted to the CO line
using analog pulses.
Содержание KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008...
Страница 13: ...Feature Manual 13 Section 1 Features and Configurations ...
Страница 183: ...1 11 M Feature Manual 183 Operating Manual References 1 3 43 Mute ...
Страница 341: ...Feature Manual 341 Section 2 Appendix ...
Страница 359: ...Feature Manual 359 Index ...
Страница 364: ...Index 364 Feature Manual X XDP EXtra Device Port 95 XDP Digital 193 XDP Wireless 338 ...
Страница 365: ...Index Feature Manual 365 ...