2.2 Programming
Programming Guide
15
Voice CODEC Settings
Gatekeeper Settings
Parameter & Description
Default
Value Range
*
Voice CODEC Priority 1st–4th
Specifies the type of CODEC for voice
communications.
Choose the appropriate CODEC for the network
environment (e.g., bandwidth, CODEC conditions of
the remote terminal). When using multiple CODECs,
set them in an appropriate priority order.
Prior to establishing a call, a negotiation takes place
over the network and the CODEC to be used will be
decided depending on the setting of this parameter.
For details about relations between bandwidth and
CODEC, refer to "Detailed Explanations" in "2.2.3
Voice Communication Parameters".
1st: G.729A
2nd: No default
3rd: No default
4th: No default
G.723.1,
G.729A,
G.711Mu,
G.711A
Parameter & Description
Default
Value Range
#
Gatekeeper
Specifies the use of a gatekeeper.
For details, refer to "Detailed Explanations".
Don’t use
Use,
Don’t use
*
Primary Gatekeeper IP Address
Specifies the IP address of the primary gatekeeper.
192.168.1.3
The following addresses
are invalid:
•
Class D addresses
•
Class E addresses
•
Loopback
addresses
*
Primary Gatekeeper Port No.
Specifies the port number of the primary gatekeeper.
1719
1 to 65535
*
Secondary Gatekeeper IP Address
Specifies the IP address of the secondary gatekeeper.
Set this parameter when setting up a secondary
gatekeeper as a redundant backup system.
192.168.1.4
The following addresses
are invalid:
•
Class D addresses
•
Class E addresses
•
Loopback
addresses
*
Secondary Gatekeeper Port No.
Specifies the port number of the secondary
gatekeeper.
Set this parameter when setting up a secondary
gatekeeper as a redundant backup system.
1719
1 to 65535
Содержание KX-TDA3480
Страница 6: ...1 1 Starting the IP GW4 Maintenance Utility 6 Programming Guide ...
Страница 51: ...2 5 Others Programming Guide 51 2 5 2 Log Out 1 Click LOGOUT in the main menu 2 Click OK to log out ...
Страница 52: ...2 5 Others 52 Programming Guide ...
Страница 64: ...3 4 Others 64 Programming Guide 3 4 2 Log Out 1 Click LOGOUT in the main menu 2 Click OK to log out ...
Страница 65: ...Programming Guide 65 Index ...