Used mainly for the control signal of DPT.
- Cch communications
Communicated by the data (8kbps) converted by the serial/parallel-
converting circuit in ASIC.
Used mainly for recognizing the terminal model.
- PT current-supply circuit
+15V/+40V is superimposed on the transmit/receive data line (D1,
D2), and fed to PT. Supply voltage is +15V for old DPT and APT,
and +40V for new DPT. It will be switched after the connected PT
is judged through communications. I/O control is as follows.
PT_POW
PT_CUR
H
H
15V
H
L
0V
L
H
40V80mA
L
L
40V20mA
For protection against risks such as an overcurrent due to +15V
short in wiring, 300mA constant-current circuit by Q1, Q2, and R25
is used. In case of +40V, 20mA and 80mA constant-current circuits
by Q4, U3, R7, and R27 are used.
The following is the flow chart of telephone switching at boot-up.
8.2.2. SLT interface
- CODEC control......IC251, IC252
Infineon-manufactured PEB2466 is used. The analog
characteristics, such as BN, frequency characteristic, level, and
sidetone, are set by the CODEC interface DCLK, CS, DOUT, and
DIN. The built-in I/O port is used for HOOK detection, DTMF
26
Содержание KX-TDA0170
Страница 13: ...6 TROUBLESHOOTING GUIDE 13 ...
Страница 14: ...14 ...
Страница 15: ...15 ...
Страница 16: ...16 ...
Страница 17: ...17 ...
Страница 18: ...18 ...
Страница 19: ...19 ...
Страница 20: ...20 ...
Страница 21: ...7 BLOCK DIAGRAM 21 ...
Страница 39: ...11 TERMINAL GUIDE OF ICS TRANSISTORS AND DIODES 12 CABINET AND ELECTRICAL PARTS LOCATION 39 ...
Страница 40: ...13 ACCESSORIES AND PACKING MATERIALS 40 ...
Страница 41: ...41 ...
Страница 52: ...ZNR52E D4EAB220A005 VARISTOR 52 ...