4.8
Extension Programming
ISDN DDI Number / Floating Number Transformation
611
39
Description
Used to convert a DDI number to an floating number in order to
put an incoming DDI call to a specific floating station.
Selection
• Floating Station : KX-TD816 – Operator / Pager 1
KX-TD1232 – Operator / Pager 1 / Pager 2 /
Pager 3 / Pager 4 / DISA 1/
DISA 2 / MODEM
• DDI Number : 1 through 6 digits
Default
All floating stations – Not stored
Programming
1.
Enter 611.
Display: F.EXT. DDI NO.
2.
Press NEXT to program the operator.
Display: Operator:
3.
Enter a DDI number.
To delete the current entry, press CLEAR.
4.
Press STORE.
5.
To program another floating station, press NEXT or PREV
until and the desired floating station is displayed.
6.
Repeat steps 3 through 5.
7.
Press END.
Conditions
Each DDI number can be one through six digits, consisting of 0 through
9.
Feature References
Section 3, Features,
Direct Dialing In (DDI)