4.8
Resource Programming
Floating Number Assignment
813
73
7.
Press END.
Conditions
• A floating number is composed of two to four numerical digits, 0
through 9.
• The first one or two digits of the floating numbers are subject to
program [100] “Flexible Numbering, (01) through (16) 1st through 16th
hundred extension blocks.”
• Floating numbers and extension numbers should be unique. Double
entry and incompatible entry for these numbers are invalid. Valid entry
example: 10 and 11, 10 and 110; Invalid entry example: 10 and 106,
210 and 21.
In order not to make an invalid entry, check the other extension
numbers in programs [003] “Extension Number Set,” [012] “ISDN
Extension Number Set, [118] “VM Extension Number Assignment”
and [130] “Phantom Extension Number Assignment.” The default of
each extension number is as follows:
[003] Extension Number Set
KX-TD816 – 101 through 116, 201 through 216
KX-TD1232 – 101 through 164, 201 through 264
[012] ISDN Extension Number Set
Not stored
[118] VM Extension Number Assignment
165 through 180
[130] Phantom Extension Number Assignment
Not stored
• You cannot leave an entry empty.