4.3
System Programming
UCD Time Table
127
35
*: Available for KX-TD1232 only.
Description
Assigns the queuing sequence in the UCD time table. The queuing
sequences are as follows:
*S1
: Sends DISA outgoing message 1
*S2
: Sends DISA outgoing message 2
*S3
: Sends DISA outgoing message 3
*S4
: Sends DISA outgoing message 4
TR
: Transfers to the overflow extension
RT
: Returns to the top of the sequence
Blank : Disconnects
1T
: Timer — 16 seconds
2T
: Timer — 32 seconds
3T
: Timer — 48 seconds
4T
: Timer — 64 seconds
Selection
• Time table number: 1 through 4
• S1 / S2 / S3 / S4 / TR / RT / 1T / 2T / 3T / 4T / Blank
Default
All time tables — Not stored
Programming
1.
Enter 127.
Display: UCD Time Table
2.
Press NEXT.
Display: Table NO?
→
3.
Enter a time table number.
To enter time table number 1, you can also press NEXT.
Display example: 1:
→ → → →
4.
Keep pressing SELECT until the desired selection is
displayed.
Display example: 1:S4
→ → → →
5.
Press
.
6.
Repeat steps 4 and 5.
4.
Press STORE.
5.
Press END.
Conditions
• “Sx” can be assigned in a space other than in the first only when
another “Sx” is assigned in the first space.
• An assignment after “TR,” “RT” or “Blank” is not available.
Feature Reference
Section 3, Features — in this manual
Uniform Call Distribution (UCD)