![Panasonic KX-TD1232CE Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/panasonic/kx-td1232ce/kx-td1232ce_installation-manual_274322005.webp)
5
2.4
Installation of Optional Cards and Units
E&M (TIE) Line Unit Connection
Installing one unit to the system allows four E&M (TIE) lines to be
connected to CO lines 05 through 08 for the KX-TD816, or CO
lines 09 through 12 or 21 through 24 for the KX-TD1232. This
unit can be installed to any of the expansion areas provided on the
front of the system.
For unit installation, refer to the procedure “Section 2.4.4 Installing
Expansion Unit (KX-TD170/KX-TD180)” in the main Installation
Manual. Steps 1 through 5 and 7 through 10 of the installation
procedure are the same as other expansion units. Step 6 is different
for each unit. Please note the following instructions below instead
of step 6 (Installation Manual) for this unit.
Note
• System Programming [109] Expansion Unit Type is required for
expansion unit location identification.
Step 6
■
If the KX-TD184 is installed, use an Amphenol Connector to connect the E&M (TIE) lines.
Insert the connector into the jack.
Note:
• Be sure to secure the inside screw, or the unit may not work properly.
• To fix the connector, refer to “
Section 2.4.4 Installing Expansion Unit (KX-TD170/KX-TD180),
Amphenol 57 Type (screw-attach-type 50-pin connector) Connection for KX-TD170” in the main
Installation Manual.
• For jack connection, please see “Cable Pin Numbers to Be Connected” on the next page.
• The KX-TD1232 is illustrated above.
P
an
as
on
ic
Connector type
Connector type
50-pin (Amphenol 57JE
series or the equivalent)
25
50
1
26
4
E
&
M
D
IG
IT
A
L
S
U
P
E
R
H
Y
B
R
ID
S
Y
S
T
E
M
To terminal Board from the
E&M (TIE) Line.