background image

•|

3

•|

KX-TCD961RUB

The underlined parts has been added to the original.

•¡

 Battery Information (Change from original page 7)

•¡

•¡

•¡

•¡

•¡

 TO REDIAL AFTER CONFIRMING THE NUMBERS IN REDIAL MEMORY (Changw from original page 10)

       The underlined parts has been added to the original.

3

  Press 

.

• The number is dialed automatically.

  • If your line has rotary or pluse service, any access numbers entered after pressing 

 will not be included when

    redialing.

* Nickel metal hydride (Ni-MH) rechargeable batteries (AAA size) are available.
    When you replace the batteries, you must program the battery type selection.

(Model KX-TCD961RUB)

3. Send batch file “SET FREQ nn” to set the clock frequency. The default value of nn is 80. Increase the value to
    increase the frequency. The clock frequency must be 10,368.000 kHz ± 0.04 kHz.

•¡

 CHECK PROCEDURE (Change from original page 48)

    The underlined parts have been changed or added to the original.

TEST EQUIPMENT REQUIRED AND EQUIPMENT SETUP

Connect a 3.9V supply to the board J5 (+), J8 (–).

INITIAL POWER + BBIC TESTS

4. Check the 3.0V supply voltage (TP10). It must be 2.85 +/– 0.3V.
5. Connect RFCLK (TP56) to CH.1 on the scope. Send batch file RFCLK1.
6. Check if the clock waveform is 10,368.000 kHz,+/– 40Hz.
7. Send batch file “SELF TEST”. The first 4digits are FLASH ROM checksum, the next 2 digits are RAM test,
    and must be 00

SET CLOCK FREQUENCY

1. Send batch file “RFCLK1”.