EEPROM serial JIG
JIG Cable: PQZZ1CD300E*
·
PC which runs in DOS mode.
·
Batch file for PC setting: PQZZTCD220SL
Note:
*: If
you
have
the
JIG
Cable
for
TCD500
series
(PQZZ1CD505E),
change
the
following
values
of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
Resistor
Old value (k
Ω
)
New value (k
Ω
)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
16.3. The Setting Method of JIG (Handset)
16.3.1. Preparation
16.3.1.1. Equipment Required
·
DECT tester: Rohde & Schwarz, CMD 60 is recommended.
·
Frequency counter: it must be precise to be able to measure 1Hz (precision; ±4ppm).
Hewlett Packard, 53131A is recommended.
·
DC power: it must be able to output at least 1A current under 2.4V for Handset.
·
Digital multi-meter (DMM): it must be able to measure voltage and current.
·
Oscilloscope
16.3.1.2. JIG and PC
16.3.2. PC Setting
16.3.2.1. Connections
16.3.2.2. PC Setting
1. Open a window of MS-DOS mode from the start-up menu.
2. Change a directory.
3. Type “SET_COM=1” from the keyboard (when COM port 1 is used for the connection).
4. Type “doskey”.
Note:
See the table below for frequently used commands.
Command name
Function
Example
rdeeprom
Read the data of EEPROM
Type “rdeeprom 00 00 FF”, and the data from
address “00 00” to “FF” is read out.
readid
Read ID (RFPI)
Type “readid”, and the registered ID is read out.
writeid
Write ID (RFPI)
Type “writeid 00 18 E0 0E 98”, and the ID “0018 E0 0E
98” is written.
setfreq
Adjust Frequency of RFIC
Type “setfreq nn”.
getchk
Read checksum
Type “getchk”.
wreeprom
Write the data of EEPROM
Type “wreeprom 01 23 45”. “01 23” is address and “45”
is data to be written.
65
KX-TCD220SLT / KX-TCA122EXT / KX-TCA121EXT
Содержание KX-TCA121EXT
Страница 23: ...23 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 29: ...9 2 Available Character Entries for SMS 29 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 35: ...10 4 Using Direct Commands 35 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 43: ...13 HOW TO REPLACE THE HANDSET LCD 43 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 47: ...14 3 Check Link 14 3 1 Base Unit 47 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 48: ...Cross Reference Power Supply Circuit P 72 Check Point Base Unit P 53 48 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 49: ...14 3 2 Handset 49 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 77: ...26 SIGNAL ROUTE 77 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 78: ...78 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 83: ...29 ENGINEERING MODE 29 1 Base Unit 83 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 86: ...29 2 Handset 86 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 90: ...31 CABINET AND ELECTRICAL PARTS LOCATION BASE UNIT 90 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 92: ...33 CABINET AND ELECTRICAL PARTS LOCATION CHARGER UNIT 92 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 93: ...34 ACCESSORIES AND PACKING MATERIALS 34 1 KX TCD220SLT 93 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 94: ...34 2 KX TCA121EXT 94 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...