Items
Check
Point
Procedure
Check or
Replace Parts
(G)* Hookswitch Check with
DC Characteristics
-
1.
Connect CN1 (Telephone Socket) to Tel-simulator which is connected with
600
Ω
.
2.
Set line voltage to 48V and line current to 40mA at off-hook condition of
normal telephone.
3.
Execute the command “hookoff”
4.
Confirm that the line current is 40mA ± 5mA.
5.
Execute the command “hookon”.
6.
Confirm that the line current is less than + 0.8mA.
CN1, L6, L7,
Q4, R23, R25,
Q5, R26, R28,
IC8, D3
(H)* DTMF Generator Check
-
1.
Connect CN1 (Telephone Socket) to DTMF tester.
2.
Execute the command “hookoff” and “dtmf_hi”.
3.
Confirm that the high frequency (1477Hz) is -6.0dBm ~ -10.0dBm.
4.
Execute the command “dtmf_lo”.
5.
Confirm that the low frequency (852Hz) is -8.5dBm ~ -12.5dBm.
IC8, R39, C41,
R49, C46, C47,
R42, R43, R44,
R45, R46, R47,
R48, C108,
C109, C40,
C36, Q8, D4
(I)*
Transmitted Power
Confirmation
-
Remove the Antenna before starting step from 1 to 7.
1.
Configure the DECT tester (CMD60) as follows;
<Setting>
·
Short A-1 and GND
·
Test mode: FP
·
Traffic Carrier: 5
·
Traffic Slot: 4
·
Mode: Loopback
·
PMID: 00000
·
RF LEVEL = -70dBm.
2.
Execute the command “testmode”.
3.
Execute the command “sendchar dmv 2 2”.
4.
Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
RFPI”.
5.
Initiate connection from Dect tester (“set up connect”)
6.
Execute the command “ANT1”.
7.
Confirm that the NTP value at ANT is 20dBm ~ 25dBm.
IC2, IC8, R124,
R125, C153,
C140, C141,
DA1, C142,
C143, C144, L3,
L4, R118, R119,
C135, R115,
R116, Q6,
C145, C147,
C149, C151,
C157, R123,
C158, C159,
C160, C161,
C162, C163,
C164, C136,
R117, R127,
C156, C154,
C155
(J)
Modulation Check and
Adjustment
-
Follow steps 1 to 6 of (I) above.
7.Confirm that the B-Field Modulation is -350 ~ -400/+320 ~ +370kHz/div
using data type Fig31.
8.Adjust the B-Field Modulation if required. (Execute the command “readmod”
and “wrtmod xx”, where xx is the value.)
IC2, IC8, R124,
R125, C153,
C140, C141,
DA1, C142,
C143, C144, L3,
L4, R118, R119,
C135, R115,
R116, Q6,
C145, C147,
C149, C151,
C157, R123,
C158, C159,
C160, C161,
C162, C163,
C164, C136,
R117, R127,
C156, C154,
C155
(K) Frequency Offset Check
-
Follow steps 1 to 6 of (I) above.
7.Confirm that the frequency offset is < ± 45kHz.
IC2, IC8, R124,
R125, C153,
C140, C141,
DA1, C142,
C143, C144, L3,
L4, R118, R119,
C135, R115,
R116, Q6,
C145, C147,
C149, C151,
C157, R123,
C158, C159,
C160, C161,
C162, C163,
C164, C136,
R117, R127,
C156, C154,
C155
54
KX-TCD220SLT / KX-TCA122EXT / KX-TCA121EXT
Содержание KX-TCA121EXT
Страница 23: ...23 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 29: ...9 2 Available Character Entries for SMS 29 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 35: ...10 4 Using Direct Commands 35 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 43: ...13 HOW TO REPLACE THE HANDSET LCD 43 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 47: ...14 3 Check Link 14 3 1 Base Unit 47 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 48: ...Cross Reference Power Supply Circuit P 72 Check Point Base Unit P 53 48 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 49: ...14 3 2 Handset 49 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 77: ...26 SIGNAL ROUTE 77 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 78: ...78 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 83: ...29 ENGINEERING MODE 29 1 Base Unit 83 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 86: ...29 2 Handset 86 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 90: ...31 CABINET AND ELECTRICAL PARTS LOCATION BASE UNIT 90 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 92: ...33 CABINET AND ELECTRICAL PARTS LOCATION CHARGER UNIT 92 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 93: ...34 ACCESSORIES AND PACKING MATERIALS 34 1 KX TCD220SLT 93 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...
Страница 94: ...34 2 KX TCA121EXT 94 KX TCD220SLT KX TCA122EXT KX TCA121EXT ...