![Panasonic KX-NS700 Скачать руководство пользователя страница 269](http://html1.mh-extra.com/html/panasonic/kx-ns700/kx-ns700_feature-manual_3765942269.webp)
–
Incoming calls to a PDN or SDN extension.
•
The PBX waits for a preprogrammed time period between the end of dialling and start of the SMDR timer
for outgoing trunk calls. When the PBX has sent out all dialled digits to the telephone company and this
timer expires, the PBX starts counting the call. A display PT shows the elapsed time of the call. The starting
time and the total duration of the call are recorded on SMDR.
®
10.3 PBX Configuration—[2-3] System—Timers & Counters—Dial / IRNA / Recall / Tone—
Dial—Analogue CO Call Duration Start (s)
If the reverse signal detection has been set (
®
2.5.4.5 Reverse Circuit), the PBX will start counting the
call after detecting the reverse signal from the telephone company regardless of the above timer.
•
If a call is transferred to an ICD group using Automatic Transfer, the condition code "TR" will not be recorded
on SMDR (
®
[Host PBX Access Code]
•
The dialled number including the Host PBX Access code will be recorded on SMDR only if the modified
number setting is selected in the ARS setting for SMDR.
•
When a Host PBX Access code is assigned to a trunk group, calls to extensions of the host PBX are not
recorded on SMDR.
•
A Host PBX Access Code can be used to record only long distance calls on SMDR when a trunk port is
connected directly to the telephone company (not a host PBX). This is allowed when the long distance
code (e.g., "0") is assigned as the Host PBX Access code. All local calls (e.g., calls that do not require a
"0" to be dialled first) are treated as extensions of the telephone company and do not get recorded on
SMDR, because in this case this PBX recognises the telephone company as the host PBX. Therefore, only
long distance calls are recorded on SMDR.
[Output to a Telnet compatible Terminal Emulator]
•
In order to activate a connection to a terminal emulator, the IP address of the mother board, port number,
user ID ("SMDR"), and password must be entered.
•
If a terminal emulator user incorrectly enters the user ID or password 3 times consecutively, an alarm will
be sent and connection will not be possible for 10 minutes.
•
Through system programming, it is possible to assign the PBX port number and password.
•
The terminal emulator application must be running constantly. If the application is terminated, call records
that occur after the termination will be recorded in the PBX’s memory. However, if the number of call records
exceeds the PBX’s capacity, older records will be deleted. Also, when the application restarts or is
reconnected, duplicated call records may be output.
[Using SMDR with applications]
SMDR data can also be monitored by applications such as Panasonic CA Call Accounting. For more
information, see your application’s documentation.
Installation Manual References
4.10 Connection of Peripherals
PC Programming Manual References
10.3 PBX Configuration—[2-3] System—Timers & Counters—Dial / IRNA / Recall / Tone—
CO Call Printout (SMDR)
14.2 PBX Configuration—[6-2] Feature—Hotel & Charge
SMDR for External Hotel Application 2—Printing Message 1–8
19.1 PBX Configuration—[11-1] Maintenance—Main
Feature Manual
269
2.22.1 Record Log Features
Содержание KX-NS700
Страница 16: ...16 Feature Manual Table of Contents...
Страница 17: ...Section 1 For Your Safety Feature Manual 17...
Страница 20: ...20 Feature Manual 1 1 1 For Your Safety...
Страница 21: ...Section 2 Call Handling Features Feature Manual 21...
Страница 42: ...PT Programming Manual References 720 Doorphone Call Destination 42 Feature Manual 2 1 2 Internal Call Features...
Страница 59: ...632 Maximum Number of Agents Feature Manual 59 2 2 2 Incoming Call Distribution Group Features...
Страница 109: ...Operating Manual References 1 2 1 Basic Calling Feature Manual 109 2 5 4 Trunk Call Features...
Страница 176: ...Feature Manual References 2 21 2 Flexible Buttons 176 Feature Manual 2 11 6 Flash Recall Terminate...
Страница 195: ...Operating Manual References 1 4 2 Holding a Call Feature Manual 195 2 13 1 Call Hold...
Страница 230: ...Operating Manual References 1 7 1 Paging 1 7 2 Answering Denying a Paging Announcement 230 Feature Manual 2 17 1 Paging...
Страница 326: ...326 Feature Manual 2 30 2 Outgoing Message OGM...
Страница 327: ...Section 3 Unified Messaging System Feature Manual 327...
Страница 377: ...Section 4 Network Features Feature Manual 377...
Страница 466: ...466 Feature Manual 4 3 6 Network ICD Group...
Страница 467: ...Section 5 System Configuration and Administration Features Feature Manual 467...
Страница 507: ...Feature Manual References 6 1 Capacity of System Resources Feature Manual 507 5 2 4 Portable Station PS Features...
Страница 560: ...560 Feature Manual 5 5 7 PING Confirmation...
Страница 561: ...Section 6 Appendix Feature Manual 561...
Страница 578: ...578 Feature Manual 6 5 6 PFMPR Software File Version 004 6xxxx...
Страница 579: ...Feature Manual 579 Notes...