4.1 Before Installation
4.1.1 Before Installation
Please read the following notes concerning installation and connection before installing the PBX and terminal
equipment.
Be sure to comply with all applicable laws, regulations, and guidelines.
Notice
Panasonic assumes no responsibility for injuries or property damage resulting from failures arising out of
improper installation or operation inconsistent with this documentation.
Safety Installation Instructions
WARNING
When installing telephone wiring, basic safety precautions should always be followed to reduce
the risk of fire, electric shock and injury to persons, including the following:
•
Never install telephone wiring during a lightning storm.
•
Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
•
Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
•
Use caution when installing or modifying telephone lines.
•
Anti-static precautions should be taken during installation.
Installation Precautions
The PBX is suitable for mounting on a 19-inch rack or placing on a desktop, and should be installed in a location
where it is accessible for inspections and maintenance.
To prevent malfunction, noise, or discoloration, follow the instructions below:
WARNING
Do not install the system in the following locations:
•
Areas where shocks or vibrations are frequent or strong. Such activity may lead to the product
falling over and causing injury, or may impair the product’s performance.
•
Areas with high amounts of dust. High amounts of dust can lead to fire or electric shock, and
impair the performance of the product.
CAUTION
Do not install the system in the following locations:
•
In direct sunlight and hot, cold, or humid places. (Temperature range: 0 °C [32 °F] to 40 °C [104 °F])
•
Areas where sulfuric gases may be present, such as near thermal springs.
•
Near devices that generate high frequencies, such as sewing machines or electric welders.
•
Locations where other objects will obstruct the area around the PBX. Be especially careful to leave at
least 5 cm (2 in) to the sides of the PBX for ventilation.
•
Locations where condensation can occur.
Notice
Do not install the system in the following locations:
72
Installation Manual
Document Version 2016-03
4.1.1 Before Installation
Содержание KX-NS700
Страница 152: ...152 Installation Manual Document Version 2016 03 4 13 Starting the PBX ...
Страница 256: ...256 Installation Manual Document Version 2016 03 6 1 Methods of Stacking Expansion Units ...
Страница 270: ...270 Installation Manual Document Version 2016 03 7 1 6 Troubleshooting by Error Log ...
Страница 302: ...302 Installation Manual Document Version 2016 03 8 6 Port Security ...
Страница 307: ...Document Version 2016 03 Installation Manual 307 Notes ...