4.3.5 MCSLC4 in the Main Unit (installed by default)
Function
•
4 extension ports for SLT with Caller ID (FSK), Message Waiting Lamp control, and 2 power failure transfer
(PFT) ports. Maximum power output of 90 V for Message Waiting Lamp control.
To Extension
Note
•
For details about power failure transfer, refer to "4.12 Power Failure Connections".
Pin Assignments
For MCSLC4 port 1-2 and port 3-4
No.
Signal Name
Function
8
1
1
TA
Tip port 1
2
RA
Ring port 1
3
Reserved
–
4
Reserved
–
5
Reserved
–
6
Reserved
–
7
TB
Tip port 2
8
RB
Ring port 2
114
Installation Manual
Document Version 2016-03