![Panasonic KX-HDV100 Скачать руководство пользователя страница 233](http://html.mh-extra.com/html/panasonic/kx-hdv100/kx-hdv100_administrators-manual_269976233.webp)
Description
Specifies the diagnose level for received RTP.
Value Range
•
0: diagnose destination IP Address and port
•
1: diagnose destination IP address
•
2: diagnose destination port
•
3: diagnose nothing
Default Value
0
RTCP_ENABLE_n
Parameter Name Example
RTCP_ENABLE_1
Value Format
BOOLEAN
Description
Specifies whether to enable or disable RTCP (Real-Time Transport
Control Protocol). For details, refer to RFC 3550.
Value Range
•
Y
(Enable RTCP)
•
N
(Disable RTCP)
Default Value
N
Web User Interface Reference
RTCP_INTVL_n
Parameter Name Example
RTCP_INTVL_1
Value Format
INTEGER
Description
Specifies the interval, in seconds, between RTCP/RTCP-XR packets.
Value Range
5–65535
Default Value
5
Web User Interface Reference
RTCP&RTCP-XR Interval (Page 117)
RTCP_SEND_BY_SDP_n
Parameter Name Example
RTCP_SEND_BY_SDP_1
Value Format
INTEGER
Description
Specifies whether to send RTCP signals by SDP (Session Description
Protocol).
Value Range
0–1
–
0: Send RTCP signals using the value specified in
"
RTCP_INTVL_n
", if the "
RTCP_ENABLE_n
" parameter is enabled.
–
1: Send RTCP signals using the value specified in the SDP attribute
"a=rtcp:".
Default Value
0
Document Version 2015-02
Administrator Guide
233
5.3.23 RTP/RTCP/RTCP-XR Settings