Web User Interface Reference
Enable c=0.0.0.0 Hold (RFC 2543) (Page 110)
SIP_HOLD_ATTRIBUTE_n
Parameter Name Example
SIP_HOLD_ATTRIBUTE_1
Value Format
INTEGER
Description
Specifies whether to set "a=inactive " or not when the call is on hold.
Value Range
•
0: send only
•
1: inactive
Default Value
0
SDP_USER_ID_n
Parameter Name Example
SDP_USER_ID_1
Value Format
STRING
Description
Specifies the user ID used in the "o=" line field of SDP.
Value Range
Max. 32 characters
Default Value
Empty string
TELEVENT_PAYLOAD
Value Format
INTEGER
Description
Specifies the RFC 2833 payload type for DTMF tones.
Note
•
This setting is available only when "
OUTBANDDTMF_n
" is set to
"
Y
".
Value Range
96–127
Default Value
101
Web User Interface Reference
Telephone-event Payload Type (Page 112)
HOLD_SOUND_PATH_n
Parameter Name Example
HOLD_SOUND_PATH_1
Value Format
INTEGER
Document Version 2015-02
Administrator Guide
223
5.3.19 SIP Settings