SIP_SESSION_TIME_n
Parameter Name Example
SIP_SESSION_TIME_1
Value Format
INTEGER
Description
Specifies the length of time, in seconds, that the unit waits before
terminating SIP sessions when no reply to repeated requests is
received. For details, refer to RFC 4028.
Value Range
0, 60–65535 (0: Disable)
Default Value
0
Web User Interface Reference
Enable Session Timer (RFC 4028) (Page 109)
SIP_SESSION_METHOD_n
Parameter Name Example
SIP_SESSION_METHOD_1
Value Format
INTEGER
Description
Specifies the refreshing method of SIP sessions.
Value Range
0–2
•
0: reINVITE
•
1: UPDATE
•
2: AUTO
Default Value
0
Web User Interface Reference
Session Timer Method (Page 109)
SIP_TIMER_T1_n
Parameter Name Example
SIP_TIMER_T1_1
Value Format
INTEGER
Description
Specifies the default interval, in milliseconds, between transmissions of
SIP messages. For details, refer to RFC 3261.
Value Range
•
250
•
500
•
1000
•
2000
•
4000
Default Value
500
Web User Interface Reference
SIP_TIMER_T2_n
Parameter Name Example
SIP_TIMER_T2_1
210
Administrator Guide
Document Version 2015-02
5.3.19 SIP Settings