14.3. Adjustment (Charger Unit)
Items
Adjustment
Point
Procedure
Check or
Replace Parts
(A)
Charging Check
-
1.
Connect Charge Contact 12
Ω
/2W register between and charge-.
2.
Measure and confirm voltage across the regigster is 2.7V ± 0.2V.
D1,R1,R2
Note:
After the measuring, sock up the solder of TP.
The connection of adjustment equipment are as shown in Adjustment Standard (Charger Unit) (P.50).
14.4. Adjustment Standard (Charger Unit)
When connecting the Simulator Equipments for checking, please refer to below.
14.4.1. Flow Solder Side View
PbF
R1
R2
TP4
TP1
TP2
TP3
Digital Volt Meter
12
Ω
/2W
(A)
Note:
(A) is refered to ADJUSTMENTS (BASE UNIT AND CHARGER UNIT) (P.44)
50
KX-TCD450RUM / KX-A145RUM / KX-TCD450R UT / KX-A145RUT
Содержание KX-A145 Series
Страница 10: ...5 LOCATION OF CONTROLS 5 1 Base Unit 5 2 Handset 10 KX TCD450RUM KX A145RUM KX TCD450RUT KX A145RUT ...
Страница 20: ...7 DISPLAY 7 1 Handset Display 20 KX TCD450RUM KX A145RUM KX TCD450RUT KX A145RUT ...
Страница 26: ...8 5 3 Phonebook Character Table 26 KX TCD450RUM KX A145RUM KX TCD450RUT KX A145RUT ...
Страница 64: ...24 SIGNAL ROUTE 64 KX TCD450RUM KX A145RUM KX TCD450RUT KX A145RUT ...
Страница 76: ...30 CABINET AND ELECTRICAL PARTS LOCATION BASE UNIT 76 KX TCD450RUM KX A145RUM KX TCD450RUT KX A145RUT ...
Страница 77: ...31 CABINET AND ELECTRICAL PARTS LOCATION HANDSET 77 KX TCD450RUM KX A145RUM KX TCD450RUT KX A145RUT ...
Страница 78: ...32 CABINET AND ELECTRICAL PARTS LOCATION CHARGER UNIT 78 KX TCD450RUM KX A145RUM KX TCD450RUT KX A145RUT ...
Страница 79: ...33 ACCESSORIES AND PACKING MATERIALS 33 1 KX TCD450RUM RUT 79 KX TCD450RUM KX A145RUM KX TCD450RUT KX A145RUT ...
Страница 80: ...33 2 KX A145RUM RUT 80 KX TCD450RUM KX A145RUM KX TCD450RUT KX A145RUT ...
Страница 87: ...36 3 Memo 87 KX TCD450RUM KX A145RUM KX TCD450RUT KX A145RUT ...