27.2. Introduction
The base unit uses a 32K bit serial EEPROM (IC4) for storing volatile parameters. All parameters
are set up before the base leaves the factory. Some of these are vital for the operation of the
hardware so a set of default parameters is programmed before the actual hardware fine-tuning
can be initiated. This document lists all default settings with a short description.
In the tables below values in a range that are similar are not repeated; i.e. Address 00 to 01
contains the value 00 simply means that the value 00 is repeated in all addresses in the range. All
values in this document are in hexadecimal notation.
Type
Name
Description
D
default
The EEPROM location is preset to the Default value by the eeprom default loader.
A
adjust
The EEPROM location is set during the production test and should not be
overwritten. The value is set by the eeprom default loader only if the location
contains all 1’s (byte: 0xFF, word FFFFh), i, e. it has never been set.
-
EEPROM location which is not set at all.
Country
Setting
x
Default - no specific country setting, so revert to default value
27.3. EEPROM Layout
27.3.1. General Setup
Address
Default
Name
Country
Setting
Type
Description
0000-01
00 E0
EepromOscillator
x
A
Frequency adjustment
0002
20
ModulationDeviation
x
A
Modulation adjustment
0020-0024
-
RFPI (ID for Base Unit)
x
A
RFPI
0025-0026
00 00
AC (Base PIN code)
x
D
AC code
0028
00
TBR22Test
x
-
TBR22 test
0030-0034
FF .. FF
IPUI_1 (ID for H/S 1)
x
D
Ipui for handset 1. If set to FF .. FF
(5bytes) the
handset is not enrolled.
0035-0039
FF .. FF
IPUI_2 (ID for H/S 2)
x
D
Ipui for handset 2. If set to FF .. FF
(5bytes) the
handset is not enrolled.
003A-003E
FF .. FF
IPUI_3 (ID for H/S 3)
x
D
Ipui for handset 3. If set to FF .. FF
(5bytes) the
handset is not enrolled.
003F-0043
FF .. FF
IPUI_4 (ID for H/S 4)
x
D
Ipui for handset 4. If set to FF .. FF
(5bytes) the
handset is not enrolled.
68
www.freeservicemanuals.info
1/2/2015
Digitized in Heiloo, Holland
Содержание KX-A142EXM
Страница 21: ...21 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 54: ...18 FREQUENCY TABLE MHz 54 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 82: ...82 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 84: ...33 ACCESSORIES AND PACKING MATERIALS 84 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 85: ...33 1 KX TCD420BXM BXS 33 2 KX A142EXM EXS 85 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 114: ...PbF R1 R2 TP4 TP1 TP2 TP3 Digital Volt Meter 12Ω 2W A www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...