13.1.1. Equipment Required
- DECT tester: Rohde & Schwarz, CMD 60 is recommended.
- Frequency counter: it must be precise to be able to measure 1Hz
(precision; ±4ppm).
Hewlett Packard, 53131A is recommended.
- DC power: it must be able to output at least 1A current under 2.4V
for Handset, 9V for JIG.
- Digital multi-meter (DMM): it must be able to measure voltage and
current.
- Oscilloscope
13.1.2. JIGs and PC
- EEPROM serial JIGs
1. I2C PCB: PQZZTCD705BX
2. RS232C cable: PQZZ1CD705BX
3. Clip cable: PQZZ2CD705BX
4. DC cable: PQZZ3CD705BX
- PC which runs in DOS mode.
- Batch file for PC setting: PQZZTCD420BX
13.2. PC Setting
13.2.1. Connections
13.2.2. PC Setting
1. Open a window of MS-DOS mode from the start-up menu.
2. Change a directory to the one with “RTX_COM” contained.
3. Type “SET RTX_COM=1” from the keyboard (when COM port 1 is
used for the connection).
4. Type “doskey”.
38
www.freeservicemanuals.info
1/2/2015
Digitized in Heiloo, Holland
Содержание KX-A142EXM
Страница 21: ...21 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 54: ...18 FREQUENCY TABLE MHz 54 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 82: ...82 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 84: ...33 ACCESSORIES AND PACKING MATERIALS 84 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 85: ...33 1 KX TCD420BXM BXS 33 2 KX A142EXM EXS 85 www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...
Страница 114: ...PbF R1 R2 TP4 TP1 TP2 TP3 Digital Volt Meter 12Ω 2W A www freeservicemanuals info 1 2 2015 Digitized in Heiloo Holland ...