![background image](http://html.mh-extra.com/html/panasonic/hit-power-230s-series/hit-power-230s-series_general-installation-manual_278226011.webp)
11
Figure 3.6
Grounding method
Using Grounding Clip with self-tapping
machine screw
Note: Use the smaller ground holes
illustrated in Figure 3.1.
Grounding Clip Assemblies: Tyco
Electronics 1954381-1.
Figure 3.7
Grounding method
Using Grounding Clip with bolt and nut
Note: Use the larger ground holes
illustrated in Figure 3.1.
Grounding Clip Assemblies: Tyco
Electronics 1954381-2
Glass
Backsheet
Frame (Longer side)
Grounding hole
(0.205” diameter (5.2mm))
Grounding Clip
8-32 Screw (Stainless steel)
Nut (Stainless steel)
Copper wire
Length
(not less than 0.63’‘(16 mm)
not more than 0.78’‘(20 mm))
Copper wire
Frame (Longer side)
Glass
Backsheet
Grounding hole
(0.165” diameter (4.2mm))
Grounding Clip
Self-tapping machine screw (Stainless steel)
Length
(not less than 0.47’‘(12 mm)
not more than 0.78’‘(20 mm))