4.5
Communication with PLC
4-35
4.5.4 Communication Settings of PLC using FPWIN GR7
Please read below to make PLC communication settings using the FPWIN GR7.
(1) Select “Options (O)” > “FP7 Configuration (C)” > “Built-in SCU”.
(2) Make the communication settings.
Set the communication settings of the communication port connected to the GT to be the
same as those of the GT.
Note) The baud rate can be changed from 9600 bps.
When changing it, it is necessary to make the both baud rates of FP series and GT series
be the same.
<Default>
- Communication mode:
MEWTOCOL-COM
- Baud rate: 9600bps
- Character bit: 8 bits
- Parity check: Odd
: Stop Bit: 1