PROGRAMMABLE DISPLAY

GT703/GT704

User's Manual

Hardware

WUME-GT703H-01

2017.07

panasonic.net/id/pidsx/global

Содержание GT703

Страница 1: ...PROGRAMMABLE DISPLAY GT703 GT704 User s Manual Hardware WUME GT703H 01 2017 07 panasonic net id pidsx global ...

Страница 2: ...e or remodel the product It could cause excessive exothermic heat or smoke generation Do not touch the terminal while turning on electricity It could lead to an electric shock Use the external devices to function the emergency stop and interlock circuit Connect the wires or connectors securely The loose connection could cause excessive exothermic heat or smoke generation Do not allow foreign matte...

Страница 3: ...n be downloaded on our website http industrial panasonic com ac e dl_center manual Unit name or purpose of use Manual name Manual code Programmable Display GT703 GT704 GT703 GT704 User s Manual Hardware WUME GT703H Programming Software FPWIN GR Ver 3 GT series Reference Manual GTWIN Ver 3 edition WUME GTWINV3REF General purpose serial communication GT series General purpose Serial Communication Ma...

Страница 4: ...ames and Functions of Parts 2 1 2 1 Names and Functions of Parts 2 2 2 1 1 GT703 2 2 2 1 2 GT704 2 3 2 1 3 Operation mode setting switches 2 4 2 1 4 Terminal Layouts of COM Port 2 5 2 2 Connection with Screen Creation Tool GTWIN 2 7 2 2 1 USB port 2 7 2 2 2 Ethernet port 2 8 3 Installation and Wiring 3 1 3 1 Installation 3 2 3 1 1 Installation Environment 3 2 3 1 2 Mounting Direction 3 3 3 1 3 Ins...

Страница 5: ... 3 13 3 5 Options 3 14 3 5 1 Time for Replacement of Battery 3 14 3 5 2 Replacement of Front Panel Protective Sheet 3 14 3 5 3 Waterproof Packing 3 15 4 Connection with PLC 4 1 4 1 Connection with PLC 4 2 4 1 1 PLC Multiple Connection 4 3 4 1 2 GT Link Connection 4 3 4 1 3 Connection with Other Companies PLCs 4 4 4 1 4 Connection with Serial Devices 4 4 4 1 5 Precautions concerning the Power Suppl...

Страница 6: ...mmunication with PLC 4 29 4 5 1 Automatic Communication Settings Function 4 29 4 5 2 Through Function 4 30 4 5 3 Communication Settings of PLC using FPWIN GR7 4 34 4 5 4 Communication Settings of PLC using FPWIN GR7 4 35 5 Troubleshooting 5 1 5 1 What to Do If an Error Occurs 5 2 5 2 Error Codes and How to Handle Them 5 7 5 2 1 About Error Codes 5 7 5 2 2 GT703 GT704 Series Error Codes 5 7 5 2 3 W...

Страница 7: ... Interface Specifications 6 5 6 2 GT704 Specifications 6 7 6 2 1 General Specifications 6 7 6 2 2 Performance Specifications 6 8 6 2 3 Function Specifications 6 9 6 2 4 Interface Specifications 6 10 6 3 Dimensions 6 12 6 3 1 GT703 Main Unit 6 12 6 3 2 GT704 Main Unit 6 13 6 4 Cable Specifications 6 14 6 4 1 AIGT8160 AIGT8162 AIGT8165 6 14 6 4 2 AIGT8175 6 14 6 4 3 AIP81842 6 14 ...

Страница 8: ... that would generate high switching surges 100mm or more Static electricity Do not touch connector pins directly to prevent static electricity from causing damage Always rid yourself of any static electricity before handling this product If excessive static electricity is applied to the panel surface the LCD panel may be damaged Power Supply Twist the wires of the power supply The unit has suffici...

Страница 9: ...oints always lit or black spots points always unlit may appear or the uneven brightness flickers or crosstalk appearance of unintended shades in the area no graphic or part is arranged may occur depending on the operating conditions Note that these phenomena are resulted from the basic characteristics of LCD panel not defects or failures of the product Battery Do not leave the battery in the unit ...

Страница 10: ...Before You Start viii ...

Страница 11: ...1 System Configuration ...

Страница 12: ...2C 5V DC Pure black AIG703WGN1B5 Silver AIG703WGN1S5 RS422 RS485 Pure black AIG703WGNMB5 Silver AIG703WGNMS5 RS232C 24V DC Pure black AIG703WGN1B2 Silver AIG703WGN1S2 RS422 RS485 Pure black AIG703WGNMB2 Silver AIG703WGNMS2 GT704 GT704M TFT monochrome LCD 640 240 dots 3 color LED backlight White red pink COM port for connecting external device USB port for connecting tool software USB2 0 compliant ...

Страница 13: ...le for connecting FP2 FP2SH COM port and FP2 Computer Communication Unit D SUB 9 pin loose wire cable 2m AIP81842 Repair parts Item name Appearance Specifications Product no Waterproof packing For GT02 GT02L GT703 10 sheets AIG02810 For GT12 GT704 AIG12810 Attachment fitting with dedicated screws For GT02 GT02L GT03 E GT12 GT703 GT704 5 pc set AIG12830 Connector 5 pc AIGT084 Options Item name Appe...

Страница 14: ...ndows 8 1 Windows 8 Windows 7 Windows Vista 800MB or more AIGSGT7JP English version AIGSGT7EN Note 1 64 bit edition of Windows Vista is not supported Use 32 bit Windows for Windows Vista Related software Freeware Item name Description Configurator WD IP address search tool Address setting for GT in Ethernet communication Note The software can be downloaded on our website http industrial panasonic ...

Страница 15: ...2 Names and Functions of Parts ...

Страница 16: ... screen creation tool software GTWIN A commercial USB cable is used Mounting position of connector for battery The connector for battery is mounted SD memory card slot An SD memory card is inserted SD memory cards can be used for copying screen data and our PLC programs and used for the logging function alarm history function and SD recipe function Ethernet port An external device is connected for...

Страница 17: ...n tool software GTWIN A commercial USB cable is used Operation mode setting switches Switches for setting the operation mode at the time of power on Using these switches enables to inhibit to move to the system menu or select the memory clear display Ethernet port An external device is connected for controlling GT using Ethernet Also this port is used for connecting to a PC when using the screen c...

Страница 18: ... the power supply on Press GT Data to clear data in the user memory Press Holding Data to clear data in the hold memory Press PLC Backup Data to clear data backed up using the PLC backup restore function When memory clear is complete Cleared is displayed For resetting the condition to the normal use turn off the power supply change the operation mode setting switches to the normal use mode and tur...

Страница 19: ...ternal device SD Send Data GT External device RD Receive data GT External device RD Receive data GT External device E Terminal resistance 24V RS232C type Pin name Name Signal direction Product no 24V AIG703WMN1B2 AIG703WMN1S2 AIG703WGN1B2 AIG703WGN1S2 0V FG Functional ground SD Send Data GT External device RD Receive data GT External device RS Send request GT External device CS Clear to Send GT Ex...

Страница 20: ...ceive data GT External device RS Send request GT External device CS Clear to Send GT External device SG Signal Ground 24V RS422 RS485 type Pin name Name Signal direction Product no 24V AIG704WMNMB2 AIG704WMNMS2 AIG704WGNMB2 AIG704WGNMS2 0V FG Functional ground SD Send Data GT External device SD Send Data GT External device RD Receive data GT External device RD Receive data GT External device E Ter...

Страница 21: ...nnection Communication with our software such as GTWIN becomes available by connecting to a PC with a USB cable Functions enabled by USB connection Through function using Panasonic PLCs Screen transfer If more than one programmable display unit are connected to a PC using the USB port the communication is not available ...

Страница 22: ...e such as GTWIN becomes available by connecting to a PC with a LAN cable Remote communication is available by communicating with LAN cable Ethernet communication function Screen transfer Communication with our PLCs using the through function Specifying the destinations to connect enables the communication with multiple units using a HUB ...

Страница 23: ...N and specify the communication parameters The factory settings are as follows IP Address IP address 192 168 1 10 Subnetmask 255 255 255 0 Default Gateway 192 168 1 1 Port no 9094 Note Setting items such as the IP address of the GT can be specified in the System Menu or GT Configuration Setting with GTWIN Network type Ethernet Title Input an arbitrary title Within 38 characters Computer Check Acqu...

Страница 24: ...o 65535 in decimal Default 9094 Specify the same setting as that of GT Communication time out Set the time out period after connection establishment for every communication within the range of 1 to 950 seconds Default 15 it is not linked to this setting until a connection is established Connection time out Set the time out period until connection establishment within the range of 1 to 180 seconds ...

Страница 25: ...3 Installation and Wiring ...

Страница 26: ...icles or saline matter Benzine paint thinner alcohol or other organic solvents or strong alkaline solutions such as ammonia or caustic soda Direct vibration shock or places always exposed to drop of water This unit is warranted by IP67 for panel mounting however this applies to initial values Influence from power transmission lines high voltage equipment power cables power equipment radio transmit...

Страница 27: ... if other parts are being installed to the panel or cables are being wired to it we recommend providing a clearance around the GT unit This prevents cables from being damaged and facilitates the installation work Also make sure that the slits in the main unit are never obstructed Model name Clearance Clearance on the surface to connect the screen transfer cable Clearance on the mounting surface wh...

Страница 28: ...ert the fittings into the grooves provided in the GT main unit and tighten the screws to secure the GT main unit to the installation panel The figure shows the example of GT704 The cross slot screwdriver no 1 must be used The tightening torque should be 0 2 to 0 3 Nm Tightening the screws too hard can cause deformation of the front panel so that the touch switches will not function properly Instal...

Страница 29: ...lling in Vertical Orientation The GT series can be installed upright The power supply connector is placed on the top side as illustrated below Select the vertical type when selecting a GT model in GTWIN GT703 back view GT704 back view ...

Страница 30: ...ly should be an insulated type and should be enclosed within a protective circuit The unit has sufficient noise immunity against the noise generated on the power line However it is recommended to take measures for reducing noise such as using an isolating transformer before supplying the power And it is recommended to take measures such as installing a ferrite core If a power supply device without...

Страница 31: ...22 to 0 3 Nm When doing RS485 communication using RS422 type Please use the following cables or equivalent Suitable wires strand wire ClassificationCross sectional view Conductor Insulator Cable diam Sample appropriate cable Size Resistance at 20 C Material Thick ness Shielded twisted pair 1 25 mm 2 AWG16 or more Max 16 8 Ω km Poly ethylene Max 0 5mm Approx 8 5 mm Hitachi Cable Ltd KPEV S1 25mm 2 ...

Страница 32: ... insulation be careful not to scratch the core wire Do not twist the wires to connect them Do not solder the wires to connect them The solder may break due to vibration After wiring make sure stress is not applied to the wire In the terminal block socket construction if the wire is fastened upon counter clockwise rotation of the screw the connection is faulty Disconnect the wire check the terminal...

Страница 33: ...oint as close as possible to the GT and keep the distance of the grounding wire short Sharing the ground with another device may have an adverse effect Therefore be sure that grounding is dedicated Conversely depending on your environment grounding may cause a problem Since the power line of the GT unit is connected to a functional earth via electronic parts the electronic parts may become damaged...

Страница 34: ...noise on the cable and no induction Use shielded wires for distribution cables Recommended cable AIGT8162 It conforms to CE marking As conditions the following wiring is required 1 Perform grounding of the cable shield 2 Perform grounding of the GT The figure shows the example of 24V DC type KEYPOINTS This product conforms to EN61131 2 for the European EMC Directive 2014 30 EU ...

Страница 35: ... wires for distribution cables Recommended cable AIGT8175 For Mitsubishi FX series When using shielded cable with crossover wiring for the RS485 transmission line grounded one end E is used to set the terminal unit It conforms to CE marking As conditions the following wiring is required 1 Perform grounding of the cable shield 2 Perform grounding of the GT KEYPOINTS This product conforms to EN61131...

Страница 36: ...ance Specifications Product no Battery for Clock 1 pc AFPX BATT When using the battery for clock attach the battery before the power supply is turned on 3 4 2 How to Install the Battery for Clock PROCEDURE Slide and remove the battery cover Insert the connector to make the red line be the side Set the battery in the circular frame Attach the battery cover Never use batteries other than AFPX BATT I...

Страница 37: ...etection of battery error 2 Operation of battery flag If the battery voltage drops too low the battery voltage low flag of the basic communication area map goes on If the battery has run down completely the battery flag of the basic communication area map goes on Please be aware that the battery flag goes on the first time that the power supply is turned on after the unit is purchased The battery ...

Страница 38: ...in 1 min 3 5 2 Replacement of Front Panel Protective Sheet About the front panel protective sheet Use the separately sold protective sheets to protect the touch panel surface and to keep it clean Replacement of Front Panel Protective Sheet Remove the peel off film attached to the front panel protective sheet Attach the front panel protective sheet Attach the front sheet to fit the liquid crystal p...

Страница 39: ...ing Remove the currently attached waterproof packing Remove the attached waterproof packing from the GT Attach the provided waterproof packing Take out one of the replacement waterproof packing pieces and attach the outer edge as shown in the illustration do not use the inner edge When doing this fasten it to the front frame being sure not to twist the waterproof packing As for the model with a gr...

Страница 40: ...Installation and Wiring 3 16 ...

Страница 41: ...4 Connection with PLC ...

Страница 42: ...nication Panasonic FP series Panasonic FP7 series GT Link Ethernet 1 1 communication Panasonic FP series Panasonic FP7 series 1 n communication Panasonic FP series Panasonic FP7 series PLC multiple connection Max 64 units For information on applicable PLCs refer to GT series Connection with other companies PLCs General purpose serial communication The general purpose serial communication mode is a...

Страница 43: ...les more than one GT to connect with one PLC Wiring of Power Supply It takes more than 10 seconds for all GT units to be operable after turning on the power supply of GT The time varies according to conditions and the number of connected GT units As for the power supply of GT it is recommended to use the wiring that enables multiple GT units to be simultaneously turned on If the power supplies of ...

Страница 44: ...l Devices Devices other than PLCs can be connected by using the general purpose serial communication mode of the GT Also PLCs made by other companies which are not put on our website can be used See our website or the GT series General purpose serial communication manual REFERENCE GT series General purpose Serial Communication Manual ARCT1F356E 4 1 5 Precautions concerning the Power Supply of 5 V ...

Страница 45: ... Connection with PLC TOOL Port Connecting to the TOOL port Usable models PLC PLC communication cable Programmable display FP X FPΣ FP0 FP0R FP2 FP2SH Mini DIN 5 pin loose wire cable AIGT8162 AIGT8165 AIGT8160 5V DC 24V DC RS232C type Connecting to the TOOL port ...

Страница 46: ...te Usable models PLC PLC communication cable Programmable display FP X AFPX COM1 Loose wire cable 5V DC 24V DC RS232C type AFPX COM2 AFPX COM3 AFPX COM4 AFPX COM5 Connecting to 1 channel RS232C type Connecting to 2 channel RS232C type As for the connection to S2 and R2 for COM2 make the same connection as that of S1 and R1 ...

Страница 47: ...4 2 RS232C Connection 4 7 Connecting to 1 channel RS485 type and 1 channel RS232C type Connecting to 1 channel Ethernet type and 1 channel RS232C type ...

Страница 48: ...to the COM port Usable models PLC PLC communication cable Programmable display FPΣ Loose wire cable 5 V DC 24V DC RS232C type Connecting to 1 channel RS232C type Connecting to 2 channel RS232C type As for the connection to S2 and R2 make the same connection as that of S1 and R1 ...

Страница 49: ...4 2 RS232C Connection 4 9 Connecting to 1 channel RS485 type and 1 channel RS232C type The connections with either one unit or two units are available ...

Страница 50: ...10 4 2 4 RS232C Connection with FP0 FP0R COM Port Connecting to the COM port Usable models PLC PLC communication cable Programmable display FP0 FP0R RS232C type 5V DC 24V DC RS232C type Connecting to the COM port of FP0 FP0R ...

Страница 51: ... the COM port FP2 FP2SH CPU FP2 Multi Communication Unit Usable models PLC PLC communication cable Programmable display CPU unit D SUB 9 pin loose wire cable AIP81842 5V DC 24V DC RS232C type FP2 Multi Communication Unit Communication block FP2 CB232 Connecting to the COM port of FP2 FP2SH ...

Страница 52: ...ween GT series and FP7 Wiring between FP7 COM0 port and GT series 24V RS232C type Wiring between FP7 COM0 port and GT series 5V RS232C type Wiring between FP7 communication cassette AFP7CCS1 RS232C 1 ch insulated type and GT series RS232C type ...

Страница 53: ...4 2 RS232C Connection 4 13 Wiring between FP7 communication cassette AFP7CCS2 RS232C 2 ch insulated type and GT series RS232C type Set the on board switch of AFP7CCS2 to 3Wire ...

Страница 54: ... 4 3 1 RS422 Connection with FP X COM Port Usable models PLC PLC communication cable Programmable display FP X AFPX COM3 Loose wire cable 5V DC type 24V DC type RS422 RS485 type Connecting to FP X communication cassette 1 channel RS485 RS422 type ...

Страница 55: ...g to the COM port Usable models PLC PLC communication cable Programmable display FP2 Multi Communication Unit Communication block FP2 CB422 D SUB 9 pin loose wire cable AIP81842 5V DC 24V DC RS422 RS485 type Connecting to the FP2 Multi Communication Unit MCU Communication block RS422 ...

Страница 56: ...ring between FP7 communication cassette AFP7CCM1 RS 422 RS 485 1 ch insulated type and GT series RS 422 RS 485 type RS422 connection Wiring between FP7 communication cassette AFP7CCM2 RS 422 RS 485 2 ch insulated type and GT series RS 422 RS 485 type RS 422 connection ...

Страница 57: ...4 3 RS422 Connection 4 17 Setting of FP7 Set the on board switches of each cassette to RS 422 For RS 422 connection set the termination resistance switches of each cassette to ON ...

Страница 58: ...nnection 4 4 1 RS485 Connection with FP0R COM Port Connecting to the COM port Usable models PLC PLC communication cable Programmable display FP0R RS485 type Loose wire cable 5V DC 24V DC RS422 RS485 type Connecting to the COM Port of FP0R ...

Страница 59: ...ion with FP X COM Port Usable models PLC PLC communication cable Programmable display FP X AFPX COM3 Loose wire cable 5V DC type 24V DC type RS422 RS485 type AFPX COM4 AFPX COM6 Connecting to FP X communication cassette 1 channel RS485 RS422 type ...

Страница 60: ... PLC 4 20 Confirm the usable GT models for the PLC multiple connection and GT link Connecting to 1 channel RS485 type and 1 channel RS232C type Confirm the usable GT models for the PLC multiple connection and GT link ...

Страница 61: ...4 4 RS485 Connection 4 21 Connecting to 2 channel RS485 type Confirm the usable GT models for the PLC multiple connection and GT link ...

Страница 62: ...ort Connecting to the COM port PLC PLC communication cable Programmable display FPΣ AFPG803 Loose wire cable 5V DC type 24V DC type RS422 RS485 type AFPG806 Connecting to 1 channel RS485 type Confirm the usable GT models for the PLC multiple connection and GT link ...

Страница 63: ...4 4 RS485 Connection 4 23 Connecting to 1 channel RS485 type and 1 channel RS232C type Confirm the usable GT models for the PLC multiple connection and GT link ...

Страница 64: ...ion cable Programmable display FP2 Multi Communication Unit Communication block FP2 CB485 Loose wire cable 5V DC type 24V DC type RS422 RS485 type Connecting to the FP2 Multi Communication Unit MCU Communication block RS485 Confirm the usable GT models for the PLC multiple connection and GT link ...

Страница 65: ...4 5 Wirings between GT series and FP7 Wiring between FP7 communication cassette AFP7CCM1 RS 422 RS 485 1 ch insulated type and GT series RS 422 RS 485 type RS 485 connection 1 1 connection PLC multiple connection GT link function ...

Страница 66: ...ommunication cassette AFP7CCM2 RS 422 RS 485 2 ch insulated type and GT series RS 422 RS 485 type RS 485 connection 1 1 connection Note As for the PLC multiple and GT link function connections refer to the connection diagrams in the previous page ...

Страница 67: ...4 4 RS485 Connection 4 27 Setting of FP7 Set the on board switches of each cassette to RS 485 For RS 485 connection set the termination resistance switches of each cassette to ON ...

Страница 68: ...esponse is sent too quickly the GT may not be able to receive it Adjust the time if necessary For our FP series FPsigma or FP X the time can be specified using the SYS1 instruction 2 Time taken until the GT sends a next command after receiving a response If a command is sent to quickly the connected device may not be able to receive it The time can be specified in the delay time setting for transm...

Страница 69: ...on GTWIN Explanation of this function Conditions when the automatic settings mode is in effect If communication is attempted the specified number of times and there is no response from the PLC the GT goes into the automatic settings mode The number of attempts is specified using the No of Retries parameter under GT Configuration Communication Parameters Handle Communication Error on GTWIN Automati...

Страница 70: ...edited or monitored through the GT series as shown below For using the through function the settings for the communication between PC and GT series and GT series and our PLC should be the same The through function does not require any special settings and is always in the standby mode Selecting a target PLC When connecting multiple PLCs it is necessary to select a target PLC for the through functi...

Страница 71: ...nication settings of GT series to those of our PLC The setting method of the GT series is as follows For details of the setting method of our PLCs refer to 4 5 3 PAGE or 4 5 5 PAGE When using GTWIN Ver 3 1 Select System Setting S GT Configuration GT Communication Parameters from the menu bar 2 Make the communication settings ...

Страница 72: ...re on your computer and specify a folder for storing the driver in the Update Driver Software dialog box Driver storage folder For Windows 64 bit edition Program Files x86 Panasonic ID SUNX Terminal GTWIN_V3 GTWIN_USB x64 For Windows 32 bit edition Program Files Panasonic ID SUNX Terminal GTWIN_V3 GTWIN_USB x86 For details of Update Driver Software rear to Procedure of installing USB Driver of GTW...

Страница 73: ...e of FPWIN When using FPWIN GR 1 Select Option O Communication Settings C from the menu bar 2 Set the network type to USB GT When using FPWIN GR7 1 Select Online L Communication Settings C from the menu bar 2 Set the computer communication port to USB GT ...

Страница 74: ...ting when connecting to the COM port Please match the communication format or transmission format and baud rate settings to those of the GT In addition to the transfer format and baud rate settings set the communication mode to Computer Link when using the COM port Note The baud rate can be changed from 9600 bps When changing it it is necessary to make the both baud rates of FP series and GT serie...

Страница 75: ...n SCU 2 Make the communication settings Set the communication settings of the communication port connected to the GT to be the same as those of the GT Note The baud rate can be changed from 9600 bps When changing it it is necessary to make the both baud rates of FP series and GT series be the same Default Communication mode MEWTOCOL COM Baud rate 9600bps Character bit 8 bits Parity check Odd Stop ...

Страница 76: ...Connection with PLC 4 36 ...

Страница 77: ...5 Troubleshooting ...

Страница 78: ...screen content or specify the correct screen number When bringing up the keyboard screen during data input an unregistered keyboard screen number was specified Create and register a keyboard screen or specify the correct keyboard screen number GT configuration data and keyboard screen data exist in the GT but there is no base screen data Transfer base screen data from GTWIN Screen displays Memory ...

Страница 79: ...ing change the setting of Backlight Control Auto Off The backlight brightness of GTWIN Configuration may be set low Select System Setting GT Configuration Basic Setup and change Backlight Brightness Setting Backlight goes off too quickly The setting of Backlight Control Auto Off is too short Change the set time of Backlight Control Auto Off Date time display is incorrect when using the GT s intern...

Страница 80: ...stalled Refer to the installation guide and install the USB driver for GT Screen is blank power supply and substitution settings noted above do not apply An error has occurred in the GT system 1 After confirming the safety of the device etc turn off the power supply and then turn it on again The GT CPU will be reset 2 Set the operation mode setting switches 2 3 and 4 to ON turn on the power supply...

Страница 81: ...yed on the password change screen The password that has been already registered is tried to be registered Enter an unregistered new password Password setting incomplete is displayed on the password change screen There are items that are not entered Enter all items Your password cannot be deleted is displayed on the password management screen Your password was tried to be deleted Your password cann...

Страница 82: ... size SD memory card is damaged and data cannot be read because SD memory card was ejected during save Stop the logging of data Eject the SD memory card after turning on the setting for stopping the trigger occurrence for all logging files in the record area control Activate the setting for stopping the trigger occurrence with switch parts etc Set not to save in the SD memory card Turn on the cont...

Страница 83: ...a is not transferred correctly Re transfer data after deleting all data 0103 Boot screen error The boot screen file is not correct Transfer the data after deleting all data 0500 Tool setting error The device that cannot be used is specified for the data Check if the used device is correct e g the word device is set in the bit area 1000 SD memory card not inserted An SD memory card is not inserted ...

Страница 84: ...or off 1040 The record area for logging was overwritten Check if an SD memory card is inserted 1041 Data cannot be written into the SD memory card Check whether the SD memory card is not write protected 1042 The memory of the SD memory card is full Delete some data in the SD memory card or prepare a new SD memory card 1044 The setting to stop writing to SD memory card has been set Cancel the writi...

Страница 85: ...lay vary Make the same setting for all GT units When the error code is always indicated There is an unconnected or faulty GT Check whether a GT indicates 20FF Reconnect the GT or turn off the bit in the connected GT designation area The communication parameters are not specified correctly Check the baud rate and transmission format for the GT The same station number is used for more than one GT un...

Страница 86: ... has been sent a command that does not match the protocol There may be a temporary error due to noise etc or error in the PLC Re supply power to the PLC and GT ER0042 NOT support error The GT has sent a non supported command to the PLC There may be a temporary error due to noise etc or error in the PLC Re supply power to the PLC and GT ER0053 Busy error The PLC is currently processing another comm...

Страница 87: ...for each part are in a readable or writable area Error codes other than these codes are based on Omron PLC error codes Be sure to use the PLC in monitor mode Otherwise communication does not work properly 5 2 6 When Connected to Modbus Code no Error Cause and solution 0001 Time up error There is no response from the PLC The connection between the GT and PLC may not be correct Check the wiring of t...

Страница 88: ...ror The address specified does not exist in the GT Check the address of the sent command 0004 Receive buffer Overflow The sent command exceeds the receivable number of bytes Check the number of bytes of the sent command 0005 Requested overflow The sent readout command exceeds the number of bytes that can send back Check the number of the read words 0006 Data error The communication condition for t...

Страница 89: ...6 Specifications ...

Страница 90: ...ith megohmmeter at default setting Vibration resistance Conforms to IEC61131 2 5 to 8 4 Hz 3 5 mm single amplitude 8 4 to 150 Hz Acceleration 9 8 m s2 10 sweeps each in X Y and Z directions 1 octave min Shock resistance Conforms to JISB3502 and IEC61131 2 147m s2 or more 3 times in the X Y Z directions EU Directive applicable standard EN61131 2 EMC Directive Noise resistance 1 000 V P P Pulse widt...

Страница 91: ...story Line graph sampling 27 5 kbytes Stored data of logging function 64 kbytes Hold GT device 2048 255 words Hold PLC device 24 words Recipe data 128 kbytes Write device 64 kbytes Battery Note 4 Application For driving the GT internal clock Life Approx 5 years at 25 C Note1 On the LCD panel bright spots points always lit or black spots points always unlit may appear or the uneven brightness flick...

Страница 92: ...tion security GT link PLC multiple connection function Logging function Through function Communication between our PLC and a computer is available by connecting the computer to the USB LAN port and the PLC to the COM port Copy function Screen data can be copied via SD memory cards Programs of Panasonic FP series PLCs can be uploaded downloaded via SD memory cards PLC backup restore function Note 5...

Страница 93: ...ls refer to the latest GTWIN HELP Connector Connector terminal block 8 pin Note 1 Note 2 Note 3 Note 1 The and terminals are the power supply terminals for driving the main unit Note 2 Regarding power supply voltage please pay due consideration to the cable length so that the applied voltage is within the operation voltage range Note 3 When tightening the terminal block requires a flat blade screw...

Страница 94: ... is insulated from the internal circuit When using it as tool port the GT cannot communicate with multiple tools PC including USB port simultaneously SD memory card Item Specifications Support media Note 1 SD memory card SDHC memory card The manufacturer that the operation check has done Panasonic Corporation Supported format standard Conforms to SD standard Please format with a format software fo...

Страница 95: ...ured with megohmmeter at default setting Vibration resistance Conforms to IEC61131 2 5 to 8 4 Hz 3 5 mm single amplitude 8 4 to 150 Hz Acceleration 9 8 m s2 10 sweeps each in X Y and Z directions 1 octave min Shock resistance Conforms to JISB3502 and IEC61131 2 147 m s2 or more 3 times in the X Y Z directions EU Directive applicable standard EN61131 2 EMC Directive Noise resistance 1 000 V P P Pul...

Страница 96: ... Line graph sampling 27 5 kbytes Stored data of logging function 64 kbytes Hold GT device 2048 255 words Hold PLC device 24 words Recipe data 128 kbytes Write device 64 kbytes Battery Note 4 Application For driving the GT internal clock Life Approx 5 years at 25 C Note1 On the LCD panel bright spots points always lit or black spots points always unlit may appear or the uneven brightness flickers o...

Страница 97: ... Operation security GT link PLC multiple connection function Logging function Through function Communication between our PLC and a computer is available by connecting the computer to the USB LAN port and the PLC to the COM port Copy function Screen data can be copied via SD memory cards Programs of Panasonic FP series PLCs can be uploaded downloaded via SD memory cards PLC backup restore function ...

Страница 98: ...efer to the latest GTWIN HELP Connector Connector terminal block 8 pin Note 1 Note 2 Note 3 Note 1 The and terminals are the power supply terminals for driving the main unit Note 2 Regarding power supply voltage please pay due consideration to the cable length so that the applied voltage is within the operation voltage range Note 3 When tightening the terminal block requires a flat blade screwdriv...

Страница 99: ...N port is insulated from the internal circuit When using it as tool port the GT cannot communicate with multiple tools PC including USB port simultaneously SD memory card Item Specifications Support media Note 1 SD memory card SDHC memory card The manufacturer that the operation check has done Panasonic Corporation Supported format standard Conforms to SD standard Please format with format softwar...

Страница 100: ...Specifications 6 12 6 3 Dimensions 6 3 1 GT703 Main Unit Dimensions Unit mm Panel cutout dimensions Unit mm Applicable panel thickness 1 0 mm to 5 0 mm ...

Страница 101: ...6 3 Dimensions 6 13 6 3 2 GT704 Main Unit Dimensions Unit mm Panel cutout dimensions Unit mm Applicable panel thickness 1 0 mm to 5 0 mm ...

Страница 102: ...Specifications 6 14 6 4 Cable Specifications 6 4 1 AIGT8160 AIGT8162 AIGT8165 6 4 2 AIGT8175 6 4 3 AIP81842 ...

Страница 103: ...Record of changes Manual No Date Record of Changes WUME GT703H 01 Jul 2017 1st Edition ...

Страница 104: ......

Страница 105: ... Ushiyama cho Kasugai shi Aichi 486 0901 Japan Telephone 81 568 33 7861 Facsimile 81 568 33 8591 panasonic net id pidsx global For our sale network please visit our website Panasonic Industrial Devices SUNX Co Ltd 2017 WUME GT703H 01 Jul 2017 PRINTED IN JAPAN ...