1-5
1.2 MELSEC-FX2N/ FX2NC/ FX3U/ FX3UC/ FX3G / FX3GC
Series
Applicable versions of GTWIN and GT series
Applicable versions of GTWIN and GT series
FX2N
・
FX2NC
・
FX3U
・
FX3UC
・
FX3G
FX3GC
GT01
Ver.1.10 or later
Cannot be used
GT02
Ver.1.00 or later
Ver.1.62 or later
GT02L
Ver.1.00 or later
Ver.1.52 or later
GT03-E
Ver.1.00 or later
Ver.1.02 or later
GT05
Ver.1.00 or later
Ver.2.22 or later
GT11
Ver.1.00 or later
Cannot be used
GT12
Ver.1.00 or later
Ver.1.92 or later
GT21
Ver.1.00 or later
Cannot be used
GT32
Ver.1.00 or later
Ver.2.32 or later
GT32-E
Ver.1.00 or later
Ver.1.32 or later
GTWIN
Ver.2.40 or later
Ver.2.E1 or later
PLC model selection
Select " Mitsubishi MELSEC-FX2N Series".
Usable devices
Bit/Word DeviceTS0000-TS0255
No.
Memo
Bit
Device
Input Relay
X0000-X0337
Output Relay
Y0000-Y0337
Internal Relay
M0000-M3071
State
S0000-S0999
Timer(contact)
TS0000-TS0255
Counter(contact)
CS0000-CS0255
Word
Device
Input Relay
X0000-X0320
Specify address expression every 20
Output Relay
Y0000-Y0320
Specify address expression every 20
Internal Relay
M0000-M3056
Specify address expression every 16 multiples
State
S0000-S0976
Specify address expression every 16 multiples
Timer(current)
TN0000-TN0255
16 Bits Counter(current)
CN0000-CN0199
32 Bits Counter(current)
CN0200-CN0255
Data Register
D0000-D7999
Note1) The addresses you can use may differ depending on the model. For details, please see the
manual for the PLC you are using.
Note2) If using an input relay, output relay and auxiliary relay in word units, please set the address in 16
point increments from 000. (X000, X020, X040 …, M000, M016, M032).
Содержание GT series
Страница 6: ...iv...
Страница 13: ...Chapter 1 Connection With Mitsubishi PLCs...
Страница 38: ...1 26...
Страница 39: ...Chapter 2 Connection With Omron PLCs...
Страница 62: ...2 24...
Страница 63: ...Chapter 3 Connection With Toshiba Machine PLCs...
Страница 67: ...Chapter 4 Connection With Rockwell Automation Allen Bradley PLCs...
Страница 73: ...Chapter 5 Connection With Siemens PLCs...
Страница 76: ...5 4 5 1 2 RS422 Connection CPU Wiring diagram GT series CPU212 CPU214 CPU215 CPU216 CPU222 RS422 RS485 type...
Страница 77: ...Chapter 6 Connection With LS Industrial Systems PLCs...
Страница 80: ...6 4...
Страница 81: ...Chapter 7 Connection With Yokogawa PLCs...
Страница 86: ...7 6...
Страница 87: ...Chapter 8 Connection With Keyence PLCs...
Страница 109: ...Chapter 9 Connection With Hitachi PLCs...
Страница 129: ...Chapter 10 Connection in Modbus RTU Mode...