![Panasonic GP-MH310 series Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/panasonic/gp-mh310-series/gp-mh310-series_technical-manual_262061011.webp)
Communications Protocol
Model: GP-HB310
Message
Auto IRIS
A0 05 00 CS FF
(Note 3)
Manual IRIS (EI OFF)
A0 05 01 CS FF
Manual IRIS (EI ON)
A0 05 02 CS FF
(Note 3)
Iris Level +
A0 05 0B CS FF
Iris Level -
A0 05 0C CS FF
Iris level operation
Iris Level Preset
A0 05 0F CS FF
Returns iris levels to factory defaults [Initial value: 40]
Iris Level Direct
A0 05 13 0p 0q CS FF
pq: Iris level 0 (Dark) - 100 (Bright) [Initial value: 40]
Manual Iris Stop +
A0 05 15 CS FF
Manual Iris Stop -
A0 05 16 CS FF
Aperture operation during manual iris [Initial value: 17]
Manual Iris Stop Preset
A0 05 19 CS FF
Returns aperture during manual iris to factory default [Initial value: 17]
Iris
Manual Iris Stop Direct
A0 05 1D p CS FF
p: Aperture 1 (Close) - 17 (Open) during manual iris
BLC OFF
A0 06 00 CS FF
Backlight compensation OFF
Multi BLC ON
A0 06 01 CS FF
Backlight compensation multifractionated evaluative metering mode (Backlight compensates
after measuring the light of the entire screen.)
Multi BLC Weight -
A0 06 04 00 CS FF
Multi BLC
A0 06 04 01 CS FF
Sensitivity settings during Multi BLC
BLC is easier to determine with a larger value [Initial value: 7]
Multi BLC Weight Preset
A0 06 05 CS FF
Returns sensitivity during Multi BLC to factory defaults [Initial value: 7]
Multi BLC Weight Direct
A0 06 06 0p CS FF
p: Direct sensitivity settings 0-15 during Multi BLC [Initial value: 7]
Multi BLC Bright -
A0 06 07 00 CS FF
Multi BLC
A0 06 07 01 CS FF
Brightness settings during Multi BLC
Larger value increases brightness when determining BLC [Initial value: 7]
Multi BLC Bright Preset
A0 06 08 CS FF
Returns brightness settings during Multi BLC to factory defaults [Initial value: 7]
Multi BLC Bright Direct
A0 06 09 0p CS FF
p: Direct brightness settings 0-15 during Multi BLC [Initial value: 7]
Center BLC ON
A0 06 0B CS FF
BLC center-weighted metering mode (Backlight compensates after measuring the light mainly in
the center.)
Center BLC Weight Preset
A0 06 0F CS FF
Returns sensitivity settings during Center BLC to factory defaults [Each initial value: 0]
* Center is always 7
A0 06 10 0p 0q 0r 0s 0t
CS
Center BLC Weight Direct
FF
Sensitivity settings during Center BLC
p: aspect
(
0: 16:9, 1: 4:3
)
q: Top(0-7) r: Bottom(0-7) s: Left(0-7) t: Right(0-7) [Each initial value: 0]
Center BLC Area Preset
A0 06 12 CS FF
Returns center area settings during Center BLC to factory defaults [Each initial value: 0]
A0 06 13 0p 0q 0r 0s 0t
CS
Center BLC Area Direct
FF
Center area settings during Center BLC
p: aspect
(
0: 16:9, 1: 4:3
)
q: x-position(0-15) r: y-position(0-15) s: x-size(0-15) t: y-size(0-
15) [Initial value: x-position: 7 y-position: 6 x-size: 2 y-size: 4]
*When x-size:0 y-size:0, it becomes 1 area.
Mask BLC ON
A0 06 15 CS FF
BLC mask mode (Backlight compensates after measuring the light, ignoring areas set as mask.)
Mask BLC Area Preset
A0 06 19 CS FF
Return mask area settings during Mask BLC to factory defaults
Mask BLC Area Direct
A0 06 1D 0p 0q 0r 0s 0t
0u
CS FF
Mask area settings during Mask
BLC (Note 1)
BLC ON
A0 06 33 CS FF
Returns to the mode before BLC OFF only when BLC OFF
Backlight
BLC by Face Detect
A0 06 20 01 CS FF
BLC by Face Detection
Shutter Speed +
A0 07 0B CS FF
Increases shutter speed by one notch (Long time mode x 64 – High speed mode 1/10000)
(Note 3)
Shutter Speed -
A0 07 0C CS FF
Decreases shutter speed by one notch (Long time mode x 64 – High speed mode 1/10000) (Note 3)
Shutter Speed Set Mode
A0 07 0E 0p CS FF
Shutter Speed Mode Settings
(Note 3)
0: Prolonged exposure shutter mode, 1: Normal mode, 3: High speed shutter mode
Shutter Speed OFF
A0 07 0F CS FF
Returns the shutter speed mode setting to normal mode setting
Shutter Long Direct
A0 07 11 0p CS FF
Shutter speed settings during prolonged exposure shutter mode
(0: x1, 1: x2, 2: x4, 3: x8, 4: x16, 5: x32, 6: x64)
Shutter Short Direct
A0 07 12 0p CS FF
Shutter speed settings during high speed shutter mode. The numbers within the brackets refer to the
PAL model (0:1/60 [1/50]
,
1:1/100 [1/120], 2: 1/250, 3: 1/500, 4: 1/1000, 5: 1/2000,6: 1/4000,
7: 1/10000) [Initial value: 0:1/60 (1/50)]
Sense Up +
A0 07 1A CS FF
Sense Up -
A0 07 1B CS FF
Increase electronic sensitivity settings
(Note 3)
Sense Up Direct
A0 07 1D 0p CS FF
p: Direct increased electronic sensitivity settings
(Note 3)
(0: OFF, 1: x2, 2: x4, 3: x8, 4: x16, 5: x32, 6: x64)
ELS OFF
A0 07 28 CS FF
After memorizing the current electrical shutter speed, set the shutter speed to 1x (1/60 [1/50]).
(The numbers within the brackets refer to the PAL model.)
Shutter
Speed
ELS ON
A0 07 29 CS FF
Returns the electronic shutter speed to the memorized value when sending ELS OFF.
CS: Checksum
FF: Terminator
−
10
−
Содержание GP-MH310 series
Страница 36: ... 34 ...
Страница 38: ...Change history 2011 1 18 the issue of ver 1 10 36 ...
Страница 43: ......