2
Supplementary instructions for
explosion-proof models
Thank you for purchasing a Panasonic product.
• This product is intended for use in non-hazardous or hazardous
location classified as EPL Gc, Zone 2.
• This product is specified Temperature class T4.
• Models FZ-X1AFAB / FZ-X1CFAB / FZ-E1BFCB / FZ-E1DFCB
have a high frequency power greater than 2 W but less than 3.5 W,
and are suitable
only
for Gas Groups IIA and IIB.
Note
• For detailed information about “Temperature class” or “Gas
Groups”, refer to EN 60079-0.
Please read this document and the unit’s Operating Instructions
carefully before using the product and keep this document in a safe
place for future reference.
Please confirm the warranty period of this product in the Operating
Instructions.
ATEX Information
ATEX Certificate of Conformity no.: CML 15 ATEX 4069X
Ex-Marking:
II 3G Ex nA nC IIB T4 Gc
Ambient temperature:
-20 °C to 40 °C
IP of degree:
IP54
Confirms to
EN 60079-0 & 60079-15