![Panasonic FY-150ZDY8 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/panasonic/fy-150zdy8/fy-150zdy8_operation-instructions-manual_4085513019.webp)
安装参考图 施工方法
Connection with power (Connection before ceiling construction)
■
Wire connection diagram
电源的连接 (在天花板施工前连接)
Relay 4
High
Switch
(To be procured locally)
Recommendation:
Distance for contact break:
More than 3mm
Rated current:
More than 15A
Second main body
Power source to be supplied to on and after second main body.
Use a device for
disconnection from
the supply, having a
contact separation of
at least 3mm in all
poles, which must be
incorporated in the
fixed wiring in
accordance with the
local electrical wiring
rules.
Power Source
220V-240V~
50Hz
Power Source
(Line)
Power Source
(Neutral)
Main unit
L
(Line)
N
(Neutral)
Brown
Blue
Blue
Blue
Blue
Blue
Blue
Blue
(
High
)
Blue
(
High
)
Yellow
Yellow
Yellow
Yellow
Yellow Yellow
Yellow
Yellow
Yellow
Grey
Grey
Grey
Grey
Grey
Black
Blue
Brown
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Capacitor
Capacitor
(
Connector
)
(
Connector
)
Connector
Connector
Connector Connector
Red
White
White
White
White
White
White
White
White
White
White
White
White
White
Relay 1
Relay 2
Relay 3
Red
Red
Red
Red
Red
Red
Red
White
Terminal
board
Orange
Orange
Orange
Orange
White
(
Extra High
)
White
(
Extra High
)
Damper
Motor
Exhaust
Air Fan
Supply
Air Fan
SW1
SW2
Common
Low
High
Damper
Damper
Low
SW1
Switch
Micro switch
Model No.
Capacitor
FY-650ZDY8
6.0 F 450VAC
FY-150ZDY8
FY-250ZDY8
2.0 F 450VAC
2.0 F 450VAC
High
Switch
(To be procured locally)
Recommendation:
Distance for contact break:
More than 3mm
Rated current:
More than 15A
Second main body
Power source to be supplied to on and after second main body.
Use a device for
disconnection from
the supply, having a
contact separation of
at least 3mm in all
poles, which must be
incorporated in the
fixed wiring in
accordance with the
local electrical wiring
rules.
Power Source
220V-240V~
50Hz
Power Source
(Line)
Power Source
(Neutral)
Main unit
L
(Line)
N
(Neutral)
Brown
Blue
Blue
Blue
Blue
Blue
(
High
)
Blue
(
High
)
Yellow
Yellow
Yellow
Yellow
Yellow Yellow
Yellow
Yellow
Yellow
Brown
Grey
Grey
Blue
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Capacitor
Capacitor
(
Connector
)
(
Connector
)
Connector
Connector
Connector Connector
Red
White
White
White
White
White
White
White
White
White
White
White
White
White
Relay 1
Relay 2
Relay 3
Red
Red
Red
Red
Red
Red
Red
White
Terminal
board
Orange
Orange
Orange
Orange
White
(
Extra High
)
White
(
Extra High
)
Damper
Motor
Exhaust
Air Fan
Supply
Air Fan
SW1
SW2
Common
Low
High
Damper
Damper
Low
SW1
Switch
Micro switch
Model No.
Capacitor
FY-350ZDY8
FY-500ZDY8
3.5 F 450VAC
6.0 F 450VAC
High
Switch
(To be procured locally)
Recommendation:
Distance for contact break:
More than 3mm
Rated current:
More than 15A
Second main body
Power source to be supplied to on and after second main body.
Use a device for
disconnection from
the supply, having a
contact separation of
at least 3mm in all
poles, which must be
incorporated in the
fixed wiring in
accordance with the
local electrical wiring
rules.
Power Source
220V-240V~
50Hz
Power Source
(Line)
Power Source
(Neutral)
Main unit
L
(Line)
N
(Neutral)
Brown
Blue
Blue
Blue
Blue
Blue
(
High
)
Blue
(
High
)
Yellow
Yellow
Yellow
Yellow
Yellow Yellow
Yellow
Yellow
Yellow
Brown
Grey
Grey
Blue
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Capacitor
Capacitor
(
Connector
)
(
Connector
)
Connector
Connector
Connector Connector
Red
White
White
White
White
White
White
White
White
White
White
White
White
White
Relay 1
Relay 2
Relay 3
Red
Red
Red
Red
Red
Red
Red
White
Terminal
board
Orange
Orange
Orange
Orange
White
(
Extra High
)
White
(
Extra High
)
Damper
Motor
Exhaust
Air Fan
Supply
Air Fan
SW1
SW2
Common
Low
High
Damper
Damper
Low
SW1
Switch
Micro switch
Model No.
Capacitor
接线图
19