Please wear appropriate personal protective equipment.
Where appropriate, use the special-purpose or dedicated parts, such as the provided
mounting fixtures, otherwise personal injury may result.
Inspect all wiring connections ensuring they meet the correct current capacity.
Disconnect power by switching off wall control first, then main switch and unplug
the power plug before working on unit.
Don't press the wall control screen. It may cause a fault code, electric shock and
screen breakage.
Select a location where the device can be easily installed and accessed.
Select a location where the device will stay dry and not directly exposed to sunshine.
Select a flat location to prevent distortion. (Distortion may damage the wall control or
cause a fault code.)
If installation position is excessive high or low, it may be difficult to view the display
screen, it's important to select the position where it can be easily viewed and
accessed. (Standard height is about 5 ft (1.5m) from the ground)
As shown in the figure, please secure
> 1 3116 (3o)
the enough space around the installation
position. Fix the base of wall control on
the wall.
60 (1500)
-3-
>1 3/16 (30)
> 1 3/16 (30)
----��
--
-·/
Wall
Control
Unit: inches (mm)