background image

Solive

Joist

Solive

Joist

Bottom flange

Bride inférieure

4 Long screws

(M4.2X30)
4 vis longues

(M4.2X30)

1. 

Insert two suspension brackets. 

2. 

Install the suspension bracket and fix the 

adaptor frame by using long screws.

During installation the distance C 
should be kept the same as the 
drywall thickness.

Note

Lors de l’installation, la distance C doit être 
identique à l’épaisseur de la cloison sèche.

Nota

1. 

Open one knock-out hole on junction 

box and connect wires.
(Refer to wiring diagram  on page 4.)

2. 

Install insulated ducts to the OA and 

EA adapter.

C

Scale

Échelle

There is the scale on the frame to adjust the C distance 

which is the same as drywall thickness
L’échelle sur le cadre sert à ajuster la distance C qui est 

la même que celle de l’épaisseur de la cloison sèche.

Suspension bracket
supports de suspension

13 1/2~16 (343~405)

4 Long screws

(M4.2X30)
4 vis longues

(M4.2X30)

1. 

Insérez deux supports de suspension.

2. 

Installez le support de suspension et fixez le 

cadre adaptateur à l’aide des vis longues.

1. 

Ouvrez un trou à défoncer sur la boîte de 

jonction et connectez les fils.
(Consultez le schéma de connexions à la page 4.)

2. 

Installez les conduits isolés sur les adaptateurs 

AA et EA.

20

10

1
2

inch/mm

20

10

1

2

inch/mm

Solive

Joist

Conduit isolé

Insulated duct

Isolation de l’adaptateur

Adaptor insulation from

Ruban

Tape

INSTALLATION

 (CEILING MOUNT)  / INSTALLATION

 (MONTAGE AU PLAFOND)

6

Conduit isolé

Insulated duct

Ruban

Tape

Adaptateur

Adaptor

Conduit de 4 po

For 4” duct / 

Conduit isolé

Insulated duct

Ruban

Tape

Adaptateur

Adaptor

Conduit de 5 po

For 5” duct / 

EN

FR

EN

FR

Unit: inches (mm)

Unités: po (mm)

Содержание FV-06VE1

Страница 1: ...fasten a prominent warning device such as a tag to the service panel 2 Avant de nettoyer ou de faire la maintenance de l appareil couper l alimentation sur le panneau de service et verr ouiller le dis...

Страница 2: ...ion 3 The special purpose or dedicated parts such as mounting fixtures must be used if such parts are provided 3 Les pi ces fins sp ciales ou d di es telles que les accessoires de montage doivent tre...

Страница 3: ...Exhaust air EA Outside air OA Stale air Air vici Indoor Int rieur Outdoor Ext rieur Amen e d air AA Climatisation Chaleur et humidit Air frais Air d vacuation EA Cooling Heat Moisture Fresh air Exhau...

Страница 4: ...ON AC 120 V 60 Hz 120 V CA 60Hz N L L CN1 N MS CN2 MAIN PCB CIRCUIT IMPRIM PRINCIPAL CN3 CN4 CN5 CN6 CN7 EA MOTER MOTEUR EA SA MOTER MOTEUR SA TEMPERATURE SENSOR CAPTEUR DE TEMP RATURE Switch PCB Circ...

Страница 5: ...7 22 1 2 1 Disconnect power supply before installing the unit 1 D branchez l alimentation lectrique avant d installer l appareil 2 Please wear gloves during the installation 2 Il est recommand de port...

Страница 6: ...distance C qui est la m me que celle de l paisseur de la cloison s che Suspension bracket supports de suspension 13 1 2 16 343 405 4 Long screws M4 2X30 4 vis longues M4 2X30 1 Ins rez deux supports d...

Страница 7: ...h bird screen No backdraft flap s vent d entr e avec grille oiseaux pas de clapet antirefoulement D 1 Finish ceiling work 2 Insert the grille mounting springs into the slots as shown and mount grille...

Страница 8: ...ts 2 Install the suspension bracket and fix the adaptor frame by using long screws During installation the distance C bottom flange should be kept the same as the interior wall thickness Note Lors de...

Страница 9: ...u Nota 1 Terminez le travail du mur int rieur 2 Ins rez les ressorts de fixation de grille dans les fentes comme illustr et fixez la grille dans le sens appropri Mur int rieur Interior wall Mur int ri...

Страница 10: ...sion diff rentielle de l air frais et de l air d vacuation respectivement puis ajustez les registres pour quilibrer les flux d air afin que la valeur du test atteigne la pression diff rentielle du d b...

Страница 11: ...ust operation Exhaust only Op ration d vacuation air sortant uniquement Exhaust air EA Air d vacuation EA Defrost operation When the outside temperature is between 23 F 5 C and 14 F 10 C OA damper con...

Страница 12: ...stops when OA Damper is closed Le ventilateur AF fonctionne 20 pi3 min lorsque le registre AA est ouvert et s arr te lorsque le registre AA est ferm 55 F 13 C 55 F 13 C 28 F 2 C 28 F 2 C 20 F 7 C 20 F...

Страница 13: ...micals to clean the ERV 5 Do not allow water to enter ERV 6 Do not immerse resin parts in water over 60 C 1 Un entretien p riodique doit tre r alis tous es 2 3 mois car des filtres obstru s peuvent en...

Страница 14: ...he filter case Alignez les fl ches du filtre AA sur le bo tier du filtre Nota Vacuum cleaner Aspirateur Filter reset button Bouton de r initialisation du filtre Filtre AA OA filter MAINTENANCE CLEANIN...

Страница 15: ...air fourni Net Air Flow D bit net d air Power Consumption W Power Consumption W Sensible Recovery Efficiency Efficacit sensible de r cup ration FV 06VE1 Heating Chauffage Cooling Climatisation Total R...

Страница 16: ......

Страница 17: ......

Страница 18: ......

Отзывы: