GENERAL SAFETY INFORMATION CONTINUED

CAUTION

Make sure that the electric service supply voltage is AC 120V, 60Hz.

Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40.

Do not disassemble the unit for reconstruction. It may cause fire or electric shock.

Ceiling joist must be subjected to static load more than five times the weight of the product.

Install the fan at least 1.5m(5feet) above the floor, and the fan must be installed above a 

counter or major appliances that serves as a barrier.

A statement to the effect that when the product is to no longer be used, it must not be left 

in place but remove, to prevent it from possibly failing.

Do not install with a method which is not approved in the instructions.

Do not install this ventilating fan where interior room temperature may exceed 104°F (40°C)

This product must be properly grounded.

Do not use this fan with any solid-state speed control device. Solid state controls may cause

harmonic distortion which can cause motor humming noise.

Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and 

the Occupation Safety and Health Act (OSHA).

Always disconnect the power source before working on or near the fan,motor or junction box.

Protect the supply wiring from sharp edges oil, grease, hot surfaces, chemicals or other objects. 

Do not kink the supply wiring.

Not for use in cooking area. (Fig.A)

The special-purpose or dedicated parts, such as mounting

fixtures, must be used if such parts are provided.

For general ventilating use only. Do not use to exhaust hazardous 

or explosive materials and vapors.

Floor

45

°

45°

Cooking

equipment

Fig. A

(Cooking area)

Do not install above or

inside this area

Provide make up air for proper ventilation.

Do not install the unit where ducts are configured as shown in below.

Bend close to duct adaptor

Squeezed duct

Successive bending

Excessive bending

Adaptor

When one switch is connected with two or more products in parallel, the unit may not function. 

Therefore, parallel connection should not be allowed.

3

NOTICE

Содержание FV-0511VQCL1

Страница 1: ...ct after installation and this booklet should be presented to users Please retain this booklet for future reference Representative models FV 0511VQL1 FV 1115VQL1 FV 0511VQCL1 Ventilating Fan FV 1115VQL1 FV 0511VQCL1 Model No FV 0511VQL1 Contents GENERAL SAFETY INFORMATION DESCRIPTION UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM SELECTOR INDICATION FV 0511VQCL1 only OPERATION FV 0511VQC...

Страница 2: ...ed by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical...

Страница 3: ...ontrol device Solid state controls may cause harmonic distortion which can cause motor humming noise Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Always disconnect the power source before working on or near the fan motor or junction box Protect the supply wiring from sharp edges oil grease hot surfaces chemic...

Страница 4: ...North America Two Riverfront Plaza Newark NJ 07102 Customer Call Center 1 866 292 7299 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Risk of Fire Type IC Inherently Protected Reor...

Страница 5: ...60 5 7 8 151 13 330 7 1 2 190 1 1 4 30 4 1 2 114 3 7 8 100 12 304 3 3 8 86 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 10 1 4 261 13 330 3 7 8 100 1 1 2 37 Part name Grille Blade Junction box Adaptor PCB box Part name No No Pick A Flow switch Lighting unit Fan body Damper 5 6 7 8 9 1 4 2 3 Part name Grille Blade Junction box Adaptor PCB box Part name No No Pick A Flow switch ...

Страница 6: ...ht Live Fan Live N Light Neutral Neutral Blue White Black Green Main control circuit Fan body LED DC Motor Junction box AC120V 60Hz Power supply AC120V 60Hz Power supply White Black Live Light Live Fan Live N Light Neutral Neutral Blue White Black Green Ground wire Main control circuit Main control circuit Factory setting 20 minutes Position For factory use Factory setting is around 50 Timer prese...

Страница 7: ...h Pick A Flow speed options The Pick A Flow switch on the face of all WhisperCeiling ventilating fans allow the option to choose 50 80 110 CFM for the FV 0511VQL1 or 110 130 150 CFM for the FV 1115VQL1 These fans can run with constant air volume depending upon the needs of the owner Pick A Flow Feature Optimum Ventilation Performance Duct length elbows and other factors increase static pressure wh...

Страница 8: ... as the spacing between joists and install to joists by drilling the other 2 tapping screws which have been fixed on it Fig 3 4 Remove junction box cover and secure conduit or stress relief to junction box knock out hole Fig 4 TM 6 Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Fig 4 5 Install a circular duct and secure it with clamps or ties and seal it with mastic or ...

Страница 9: ...ther mounting spring into the slot as shown and mount grille to fan body Fig 9 12 Adjust Pick A Flow switch Refer to indication on FEATURE 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 CAUTION CAUTION 10 Insert the grille mounting spring on the wiring side into the slot and insert the plug connector into the housing of the lighting unit Fig 8 Before ...

Страница 10: ...achine screw M4X8 to the suitable hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth TM Fig 12 CAUTION WARNING WARNING Disconnect power source before working on unit Routine maintenance must be done every year Please wear gloves during the cleaning work Never use gasoline benzene thinner or any other such chemicals for cleaning the ventilating fan D...

Страница 11: ...roblem with recessed light fixtures or some competitor s fan light combination Our efficient cool running motors do not create enough ambient heat to be subjected to these limitations The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest duct routing possible for best performance and avoid installin...

Страница 12: ...e a minimum of maintenance Should your unit require service or parts call Panasonic Call Center at 1 866 292 7299 USA or 1 800 669 5165 Canada Printed in Mexico P0717 0 11QCL1420B PRODUCT SERVICE Panasonic Corporation of North America Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 www panasonic ca Two Riverfront Plaza Newark NJ 07102 www panasonic com ...

Отзывы: