English
SELECTOR INDICATION (FV-0511VQCL1 only)
Humidity
preset selector
Selector indications
on blower unit
Timer
preset selector
FV-0511VQCL1
FV-0511VQL1 , FV-1115VQL1
WIRING DIAGRAM
Main control circuit
Humidity sensor
Fan body
Motion sensor
LED
DC
Motor
Junction box
AC120V
60Hz
(Power supply)
AC120V
60Hz
(Power supply)
Selector
White
Black
Live
(
Light
)
Live
(
Fan
)
Live
(
N.Light
)*
Neutral
Neutral
Blue
White
Black
Green
Main control circuit
Fan body
LED
DC
Motor
Junction box
AC120V
60Hz
(Power supply)
AC120V
60Hz
(Power supply)
White
Black
Live
(
Light
)
Live
(
Fan
)
Live
(
N.Light
)*
Neutral
Neutral
Blue
White
Black
Green
(Ground wire)
Main control
circuit
Main control
circuit
Factory setting : 20 minutes.
Position ” ” : For factory use
Factory setting is around 50%.
Timer preset selector positions
Timer
[min]
Humidity selector range from around 30% to 80%
0.5
1
2
3
5
10
20
30
60
Timer
Humidity
setting
6
Night light
(Ground wire)
*