background image

7

FV-CSVK1 Condensation Sensor module

 turns the base fan on or 

boosts to higher speed when humidity is detected when used in 
combination with the FV-VS15VK1. The Condensation Sensor works 
based on calculations from the Psychrometric Chart, or combination 
of Relative Humidity (RH) and Temperature. This allows the fan to 
anticipate the formation of condensation and automatically turn on 
when needed to expel humid air. The Condensation Sensor is pre-set 
to run for 20 minutes; it will then check the RH and Temperature to 
detect if the fan needs to run for another 20 minutes cycle.

FV-MSVK1 Motion Sensor module 

turns the base fan on or boosts 

to higher speed when motion is detected when using in combination 
with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20 
minutes; it will then re-check for movement; if detected the fan will 
run for another 20 minutes cycle. The Motion Sensor detects within 
the range shown below.

TM

FV-NLVK1 Nite-Glo  LED Night Light module 

automatically  turns on 

when ambient light levels are met. Turning the dial on the Modular 
Nite-Glo Component to ‘DARK’ is ideal if the fan is in an isolated room 
with little ambient light from nearby rooms. Turning the dial to 
‘BRIGHT’ is ideal if there is light spill from nearby rooms. (Note that it is 
necessary to connect wall switch when only plug in FV-NLVK1, fan can 
operate on high speed with wall switch control, fan can also operate 
on low speed when used in combination with the FV-VS15VK1.)

INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED 

The distance that motion 
can be detected is limited
to 10 feet (3m). The field 
of view of the sensor is 90

°

.

(Room temperature is 25 C).

PLUG ‘N PLAY Modular Component Accessories

Sold Separately, Not Included With Base Model Fan

PLUG ‘N PLAY Modular Component Accessories

Sold Separately, Not Included With Base Model Fan

FV-CSVK1 + FV-MSVK1

FV-CSVK1 + FV-VS15VK1

Turns the fan on for 20 minutes when either 
motion or excess humidity is detected.

Cycles the fan to  high speed from low speed 
for the amount of time selected on the Control 
Dial based upon detection of excess humidity.

MOTION (PLUG ‘N PLAY FUNCTION DEVICES) 

PLUG ‘N PLAY Modular 
Components used in 
Combinations

FV-MSVK1 + FV-VS15VK1

Cycles the fan to  high speed from low speed 
for the amount of time selected on the Control 
Dial based upon motion within the room.

Fan 
operation

Time delay 
operation

OUTSIDE

Human 
active

Motion

Module FV-MSVK1, 

FV-CSVK1 (Not 

included)

INSIDE

FV-CSVK1 only

Fan 
ON/OFF

20 minutes 
time delay

FV-MSVK1 only

Fan 
active

At low 
speed

When motion or 
excess humidity is 
detected, fan runs 
at high speed.

Remains running 
at high speed until 
the delay time has 
passed.

FV-CSVK1 + FV-VS15VK1

Fan 
Hi/Low speed

Depend on 
FV-VS15VK1 Time 
delay setting

FV-MSVK1 + FV-VS15VK1

Содержание FV-05-11VKS1

Страница 1: ...IPTION UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM FEATURE INDICATION PLUG N PLAY FUNCTION DEVICES MOTION PLUG N PLAY FUNCTION DEVICES INSTALLATION PLUG N PLAY FUNCTION DEVICES INSTALLATI...

Страница 2: ...d shower enclosures For Your Safety To reduce the risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions Explan...

Страница 3: ...r dedicated parts such as mounting fixtures must be used if such parts are provided Do not install the unit where ducts are configured as shown in Fig A Adaptor CAUTION Canada only Not to be installed...

Страница 4: ...100 105 110 Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms DESCRIPTION These products are listed by UL under UL file No E78414 These products use a sirocco fan driven by a DC motor powered b...

Страница 5: ...V 11 15VK1 4 5 8 116 7 8 22 5 1 26 FV 11 15VK1 10 11 12 11 FV 05 11VKS1 Unit inches mm 13 330 3 1 4 81 3 1 2 88 7 3 8 190 6 3 8 163 5 7 8 148 5 7 8 148 3 7 8 98 10 1 4 260 12 1 8 307 10 1 4 260 3 7 8...

Страница 6: ...the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM M...

Страница 7: ...ecessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 INDICAT...

Страница 8: ...plug connector from receptacle and remove adaptor from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As sh...

Страница 9: ...page 5 Follow all the local electrical safety codes as well as the National Electrical Code NEC Using UL approved wire nuts connect house power wires to ventilating fan wires Fig 5 Fig 5 FV 05 11VKS1...

Страница 10: ...1 Remove the existing fan and cut ceiling openning 2 Follow the step 1 4 5 on page 8 and step 7 on page 9 Before connect the circular duct to the adaptor should pull down the circular duct from the c...

Страница 11: ...FV MSVK1 or FV NLVK1 Pull down the mounting spring that without lead wire passed side and remove motion sensor or LED night light as shown in Fig 16 Squeeze mounting spring and pull down carefully Dis...

Страница 12: ...d directly over the fan housing in the attic Our fans and fan light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor s fan light...

Отзывы: