Panasonic FV-05-11VKS1 Скачать руководство пользователя страница 2

2

Use  this  unit  only  in  the  manner  intended  by  the  manufacturer.  If  you  have  any  questions, 
contact  the  manufacturer. 

Before  servicing  or  cleaning  unit,  switch  power  off  at  service  panel  and  lock  the  service 
disconnecting  means  to  prevent  power  from  being  switched  on  accidentally.  When  the 
service  disconnecting  means  cannot  be  locked,  securely  fasten  a  prominent  warning  device, 
such  as  a  tag,  to  the  service  panel.

Installation  work  and  electrical  wiring  must  be  done  by  qualified  person(s)  in  accordance  with
all  applicable  codes  and  standards,  including  fire-rated  construction.

When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage  electrical  wiring  and  other 
hidden  utilities.

Ducted  fans  must  always  be  vented  to  the  outdoors.

If  this  unit  is  to  be  installed  over  a  tub  or  shower,  it  must  be  marked  as  appropriate  for  the 
application  and  be  connected  to  a  GFCI(Ground  Fault  Circuit  Interrupter)  -  protected  branch 
circuit. 

These  models  are  UL  listed  for  tub  and  shower  enclosures.

For  Your  Safety

To  reduce  the  risk  of  injury,  loss  of  life,  electric  shock,  fire,  malfunction,  and  damage  to 
equipment  or  property,  always  observe  the  following  safety  precautions.

Explanation  of  symbol  word  panels

The  following  symbol  word  panels  are  used  to  classify  and  describe  the  level  of  hazard,  injury,  and 
property  damage  caused  when  the  denotation  is  disregarded  and  improper  use  is  performed.

To  reduce  the  risk  of  fire,  electric  shock  or  injury  to  persons,  observe  the  following  :

CAUTION

Denotes  a  potential  hazard  that  could  result  in  serious 
injury  or  death.

Denotes  a  hazard  that  could  result  in  minor  injury.

The  following  symbols  are  used  to  classify  and  describe  the  type  of  instructions  to  be  observed.

This  symbol  is  used  to  alert  users  to  a  specific  operating  procedure  that  must  not  be 
performed.

This  symbol  is  used  to  alert  users  to  a  specific  operating  procedure  that  must  be  followed 
in  order  to  operate  the  unit  safely.

WARNING

WARNING

This  symbol  is  used  to  alert  users  not  to  disassemble  the  equipment.

This  symbol  is  used  to  alert  users  to  make  sure  of  grounding  when  using  the  equipment 
with  the  grounding  terminal.

WARNING

Содержание FV-05-11VKS1

Страница 1: ...IPTION UNPACKING SUPPLIED ACCESSORIES DIMENSIONS WIRING DIAGRAM FEATURE INDICATION PLUG N PLAY FUNCTION DEVICES MOTION PLUG N PLAY FUNCTION DEVICES INSTALLATION PLUG N PLAY FUNCTION DEVICES INSTALLATI...

Страница 2: ...d shower enclosures For Your Safety To reduce the risk of injury loss of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions Explan...

Страница 3: ...r dedicated parts such as mounting fixtures must be used if such parts are provided Do not install the unit where ducts are configured as shown in Fig A Adaptor CAUTION Canada only Not to be installed...

Страница 4: ...100 105 110 Two Bedrooms Three Bedrooms Four Bedrooms Five Bedrooms DESCRIPTION These products are listed by UL under UL file No E78414 These products use a sirocco fan driven by a DC motor powered b...

Страница 5: ...V 11 15VK1 4 5 8 116 7 8 22 5 1 26 FV 11 15VK1 10 11 12 11 FV 05 11VKS1 Unit inches mm 13 330 3 1 4 81 3 1 2 88 7 3 8 190 6 3 8 163 5 7 8 148 5 7 8 148 3 7 8 98 10 1 4 260 12 1 8 307 10 1 4 260 3 7 8...

Страница 6: ...the high speed setting Selecting a particular TIME option will cause the fan to run for the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM M...

Страница 7: ...ecessary to connect wall switch when only plug in FV NLVK1 fan can operate on high speed with wall switch control fan can also operate on low speed when used in combination with the FV VS15VK1 INDICAT...

Страница 8: ...plug connector from receptacle and remove adaptor from fan body by removing the machine screw M4X6 before installation Fig 1 IMPORTANT Remove the tape from damper and adaptor before installation As sh...

Страница 9: ...page 5 Follow all the local electrical safety codes as well as the National Electrical Code NEC Using UL approved wire nuts connect house power wires to ventilating fan wires Fig 5 Fig 5 FV 05 11VKS1...

Страница 10: ...1 Remove the existing fan and cut ceiling openning 2 Follow the step 1 4 5 on page 8 and step 7 on page 9 Before connect the circular duct to the adaptor should pull down the circular duct from the c...

Страница 11: ...FV MSVK1 or FV NLVK1 Pull down the mounting spring that without lead wire passed side and remove motion sensor or LED night light as shown in Fig 16 Squeeze mounting spring and pull down carefully Dis...

Страница 12: ...d directly over the fan housing in the attic Our fans and fan light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor s fan light...