97
4.3.7.
Information Codes: 459, 494, 495
START
END
Check the line connection
between the telephone jack on
the wall and the MJR PCB.
Is communication with the
reference unit successful?
Yes
No
Yes
No
Does the problem still occur?
1. Replace the MJR PCB.
2. Replace the SC PCB.
No
1. Check the remote unit in
question.
(Remote unit is defective)
2. Refer to Sect. 4.6.
If the telephone line frequently
disconnects at the beginning of
each communication, ask the
telephone company to check
the line.
Does the trouble occur
regardless of the remote unit?
END
Yes
Check the telephone line
condition.
Содержание Facsimile UF-590
Страница 14: ...14 4 Driver No TWAIN 5 2 Sided Scanning No Items Description Remarks UF 580 UF 780 UF 590 UF 790 ...
Страница 17: ...17 1 4 Control Panel For USA and Canada UF 790 UF 780 790 780 ...
Страница 18: ...18 For Other Destinations UF 590 UF 580 ...
Страница 27: ...27 10 Remove 2 P6A Bushings 316 11 Remove the Eject Roller 303 10 11 ...
Страница 33: ...33 11 Remove 2 Screws 4N 12 Remove the Paper Feed Rollers 518 11 12 ...
Страница 238: ...238 807 807 808 805 804 802 801 811 810 810 809 803 806 K A C D E F G H I J B 8 1 3 4 5 6 7 2 2 2 Fig 8 Cassette ...
Страница 290: ...290 10 9 CCD PC Board 4 3 2 1 D C B A 1 2 3 4 Drawing Name CCD PC Board 1 1 Model UF 580 590 780 790 5V 5V ...
Страница 293: ...293 10 12 Power Supply Unit 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 1 4 Model UF 580 590 780 790 ...
Страница 294: ...294 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 2 4 Model UF 580 590 780 790 ...
Страница 295: ...295 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 3 4 Model UF 580 590 780 790 ...
Страница 296: ...296 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 4 4 Model UF 580 590 780 790 ...
Страница 297: ...297 4 3 2 1 D C B A 1 2 3 4 Drawing Name LVPS 1 1 Model UF 580 590 780 790 ...
Страница 298: ...DZZSM00158 ...