3-1
Maintenance
Cleaning Replacement
Section III Maintenance
3.1 Maintenance chart
• In addition to the following maintenance table, the platen mat must be cleaned as
part of regular service calls.
• The timing of regular maintenance is determined on the basis of the number of
ADF original feed count. (F7-06)
Original feed roller/DFP roller
Original pick-up roller
Original detecting sensor
Registration sensor
Original exit sensor
Original support roller
Transport roller
Registration roller (upper)
Registration roller (lower)
Original exit roller (left)
(right)
Torque limiter spring
FFPMA0604
FFPMA0605
GP1A73A
FFPMA0609
FFPMA0607
FFPMA0606
FFPMA0608
FFPMA0602
FFPMA0603
FFPLR0287
Brush, air blower,
isopropyl alcohol (IPA)
Note: •Rollers should be
cleaned with water
and cloth.
•Use of IPA
(Isopropyl alcohol)
should be used
sparingly.
Part name
Part number
Remarks
3.2 Cleaning
Clean each rollers.
Maintenance interval
120,000
120,000
–––
–––
–––
–––
–––
–––
(Lubrication)
Exit roller
Original feed roller
Pick-up roller
Registration roller
Transport roller
Original support roller
60,000
60,000
120,000
60,000
60,000
60,000
60,000
60,000
120,000
DFP roller (lower)