MAINTENANCE

Make sure to disconnect the 

power before cleaning the 

product.

WARNING

(Otherwise, the product might operate with 

the possibility of electric shock or injury.) 

Notice

Do not operate the product when the 

composite and deodorizing filter is removed.  

(The composite and deodorizing filter cannot 

function while it is removed. Dust will be 

inhaled into product inner parts, and causes 

the product breakdown. )  

When maintenance, do not leave the removed 

parts unattended.  
(Otherwise, it may cause tripping or damage.)

When using chemically treated cloth, make

sure to follow the instructions carefully.

Do not use the 

detergents 

shown on the 

right.

Polish

A

lk

al

in

e

de

te

rg

en

t

Th

in

ne

r

Bl

ea

ch

K

er

os

en

e

A

lc

oh

ol

Cleaning method 

Wipe off any dust and dirt using a well 

wrung-out soft cloth

 Body and Front panel

(about once a month)

Do not wipe it with a hard cloth or hardly.

Otherwise, the surface may be damaged.

Check page 8 to 10 for opening and closing 

methods. 

1

8~10

Lens(top left and 

top right)

Dry cotton swab

Wipe the dirt off the lens with a dry

cotton swab

(about once every 3 months)

Remove the cover of dirt sensor as shown 

below.

Wipe the lens with a dry cotton swab as 

shown below.

3

1

Do not insert a cotton swab in other parts.

Be sure to disconnect power before cleaning.

You can use a light in order to see lens 

clearly.

 Dirt sensor

Wash with water

Pull out horizontally. (when installing, Insert 

horizontally until it reaches the end)

 Pre-filters

(about once a month)

Soak a soft cloth in warm water or water 

with a neutral kitchen detergent, then scrub 

to remove the stain.

Wipe the lens periodically. 

(The sensor may not function normally with 

accumulation of moisture and smoke from 

cigarette.)

Содержание F-PZT175H

Страница 1: ...G 22 23 SPECIFICATIONS BACK COVER SPECIFICATIONS BACK COVER 2 4 4 4 6 6 8 8 10 10 15 11 PM2 5 12 13 14 15 16 18 16 17 17 18 18 18 21 21 22 22 23 Panasonic 2 4 Thank you very much for purchasing this Panasonic product Please read these operating instructions carefully before operation and maintenance Also be sure to read the SAFETY PRECAUTIONS section P 2 4 before use Failure to comply with instruc...

Страница 2: ...of causing death or severe injury Those things shown in this column indicate that there is possibility of causing minor injury or damage to properties This symbol indicates an action that must not be performed This symbol indicates an action that must be performed The following symbols are used to indicate the type of instructions that need to be followed The symbols given below are examples WARNI...

Страница 3: ...r to check and repair Otherwise this product may cause injuries once it falls off If you will not use this product any more remove the product CAUTION Do not operate this product in places where indoor fumiga tion type insecticides are being used Ventilate the room with fresh air thor oughly after using insecticides before operating the product Chemical residue may build up inside the product and ...

Страница 4: ...malfunction may be caused OPERATING REQUIREMENTS PM2 5 PM2 5 PM2 5 nanoe CADR 400 m3 h Equipped with the nanoe technology for thorough purification The clean air volume for formaldehyde CADRformaldehyde is higher than 400 m3 h and thus decoration pollutants like formaldehyde can be removed PRODUCT FEATURES With the efficient composite and deodorizing filter and large air volume design it brings yo...

Страница 5: ...and above in 4 hours Test number 24_0301_1 4 99 24_0301_1 2 3 Test organization Panasonic Corporation Analysis Center Test method measure the allergens adhered on the fabric in a test space of 23 m3 with ELISA method Inhibiting method release nanoe Target pollen allergens Test outcome inhibited 88 and above in 8 hours BAA33 130402 F01 Test organization Japan Food Research Laboratories Test method ...

Страница 6: ...st organization Panasonic Corporation Analysis Center Test method conduct verification by using 6 phase odor intensity in a test space of 23 m3 Deodorizing method release nanoe Target adhered cigarette odor Test outcome odor intensity dropped to 1 2 after 2 hours BAA33 130125 D01 23 m3 6 nanoe 2 1 2 BAA33 130125 D01 This product is not a medical equipment nanoe and the nanoe mark are trademarks of...

Страница 7: ... and automatically adjusts the brightness of the indicators and the air volume P 20 Light sensor Blue Indicates clean Purple Indicates slight dirty Red Indicates dirty Show the air pollution levels detected by dirt sensor and odor sensor This indicator lights on to indicate that you need to clean the composite and deodorizing filter P 17 Displays the PM2 5 concentration detected by the dirt sensor...

Страница 8: ...l lock Replacement composite and deodorizing filter MAIN PARTS IDENTIFICATION nanoe nanoe nanoe nanoe 18 3 PM2 5 3 Notice You can touch and hold and simultaneously for about 3 seconds to close the PM2 5 concentration timer display window and the lit indicators except for the lit control buttons and air volume indicator touch and hold them again for about 3 seconds to turn them back on nanoe indica...

Страница 9: ...ces upward The arrow on the composite and deodorizing filter 2 pcs faces to the front panel and install it into the body 2 Install filters 2 Arrow Notice SETUP 5 3 2 15 Notice Guide lock Guide lock When opening the front panel pay attention to the gap and corner position between the two panels to prevent your fingers being clamped Lift up the front panel with both hands while holding down the guid...

Страница 10: ...or baseline is updated automatically depending on the level of cleanliness in the room 7 Power on Power on OPERATION This product adopts touch screen operation contact area is as large as possible when using finger to press if contact area is too small may result in no response after touch If power is disconnected while operating when it is connected again the product will automatically restart an...

Страница 11: ... volume according to the air pollution detected by sensor and use appropriate air volume to purify air Each press of the button the air volume indicator switches in the order shown below Turn on or off Select appropriate air volume for purifying air One button to operate silently Press the button again the product stops operating When operation is stopped with the power connected The PM2 5 concent...

Страница 12: ...er shown below on the PM2 5 concentration timer display window About 15 seconds after the selection is completed the setting will be automatically saved and the setting is completed Method to set up the PM2 5 concentration baseline When the indoor PM2 5 concentration is lower than the PM2 5 concentration baseline after press this button PM2 5 mode will automatically stop after approximately 1 minu...

Страница 13: ...nd the setting is completed Timer 2 hours timer Stop operation automatically after 2 hours 4 hours timer Stop operation automatically after 4 hours 8 hours timer Stop operation automatically after 8 hours 12 hours timer Disable the timer PM2 5 Concentration Timer Display Window Stop operation automatically after 12 hours The PM2 5 concentration timer display window will automatically switch to sho...

Страница 14: ...the remote control holder fixed by magnet The use of the buttons on the remote control is consistent with the use of buttons on the product Page 11 13 When using please point the signal transmitter to the product and use it within the effective range of the remote control receiver Effective range of receiver 5 5 m from the front of the product and within a 60 degree angle range The tape must be re...

Страница 15: ...ttery holder Use your fingernail to push right at and hold it while pulling out the battery holder at If the battery is used incorrectly it may generate heat and rupture which may cause injury or product failure Please observe the following Panasonic CR2025 20 OPERATION Notice WARNING Remote control touch screen Battery replacement method Panasonic CR2025 is recommended Safety precautions for batt...

Страница 16: ...t using a well wrung out soft cloth Body and Front panel about once a month Do not wipe it with a hard cloth or hardly Otherwise the surface may be damaged Check page 8 to 10 for opening and closing methods 1 8 10 Lens top left and top right Dry cotton swab Wipe the dirt off the lens with a dry cotton swab about once every 3 months Remove the cover of dirt sensor as shown below Wipe the lens with ...

Страница 17: ...Composite and deodorizing filter When the filter clean indicator is on about once a month Composite and deodorizing filter After cleaning connect the power press and simultaneously for about 3 seconds the filter clean indicator is off and the reset is completed Never wash the filter with water The filter side is free of maintenance When vacuuming do not apply too much pressure as the filter may be...

Страница 18: ... power even at rest Maintain the product as usual Filter replacement Notice The filter which needs to exchange cannot be used again even is cleaned please dispose it as non flammable garbage If the product is used in a room especially hotel with strong odor such as aromatic smell cigarette smoke or barbecue smell these odors may adhere to the filter when the adsorption capacity of the filter reach...

Страница 19: ... etc Oil fog stated water drip Odor sensor The sensor sensitivity is adjustable The factory setting is b2 medium sensitivity When the product stops operating touch and hold for about 3 seconds At this moment all the control buttons and the filter replacement indicator light on and the air volume indicator flashes Under such condition each time you touch the PM2 5 concentration timer display window...

Страница 20: ...Detects the indoor brightness by the light sensor and automatically adjusts the brightness of the indicators and the air volume When the room becomes dark during bed time the indicator goes dim or lights off and the product runs with low air volume 1 The sensitivity of the sensor can be adjusted The default setting is sensitivity 1 Notice When the air volume is set to High Med or Low the air volum...

Страница 21: ...n of indoor dust is predicted the product starts operating before the indoor air pollution spreads When the air volume is set to auto Not all pet movements can be detected About human sensor Normal sensitivity High sensitivity No human activity sensing 150 2 5 m 25 The sensing distance is about 2 5 m The sensing angle is about 150 At a room temperature of 25 Detection range FURTHER INFORMATION FAQ...

Страница 22: ...ail to function when the body temperature is the same as the ambient temperature Is the human activity sensor stained Use a dry cotton swab to clean the human activity sensor 19 Such problems may occur because of the difference in sensitivity of sensor P 19 21 You can disable it by setting the sensitivity of the human activity sensor P 21 TROUBLESHOOTING 16 Possible situation Please confirm the fo...

Страница 23: ...annot be removed Has the product ever been used in a room with strong odor If the product is used in a room with strong odor such as aromatic smell cigarette smoke or barbecue smell the filter replacement period may be shortened If you use the product in such environments it is recommended to open the air ventilation system or open the windows to ventilate the room at the same time If there is sti...

Страница 24: ...ped with the power connected PM2 5 is still being detected and is displayed Under the condition with the power connected Turbo High Medium Silent Width 758 mm X Deep 220 mm X Length 1412 mm OPTIONAL ACCESSORIES Please disconnect the power and contact the dealer for repair Call the dealer PM2 5 F Product may be out of order When PM2 5 Concentration Timer display window shows the letter F with two n...

Отзывы: