EN
EN
- -
EN
EN
700 (7140)
600 (6120)
500 (5100)
400 (4080)
300 (3060)
200 (2040)
100 (1020)
0
N·m (kgf·cm)
11
5
10
15
20
25
30
M24
M20
M18
M16
Torque setting level
Tightening torque
EYFPA1C, EYFPA1J
300 (3060)
250 (2550)
200 (2040)
150 (1530)
100 (1020)
50 (510)
0
N·m (kgf·cm)
11
5
10
15
20
25
30
M18
M16
M14
M12
Tightening torque
Torque setting level
EYFNA1C
Setting the snug point detec
tion level
[Fig.17]
1. Press the A button.
The snug point detection level setting
value will be displayed.
[Fig.18]
. Press the and buttons to set the best
snug point detection level for the work
you’re performing.
. Press the OK button to accept the number
of torque stages and the snug point detec-
tion level.
The tool’s panel will flash and then light up
continuously.
Snug point detection level guidelines
Display
Snug point
detection level
Applications
(reference)
L1
Low
(Use for work
characterized by
low loads before
the snug point is
reached.)
• Tightening bolts in
materials that are
easily cracked or
deformed, etc.
L
High
(Use for work
characterized
by high loads
before the
snug point is
reached.)
• Tightening bolts
in materials with
misaligned holes,
etc.
• Tightening self-
tapping screws,
etc.
CAUTION:
Set the snug point detection level from
“L1.” Setting the snug point detection
level from “L” may result in cracking or
deformation of the target material.
If the tool stops before the snug point at
snug point detection level “L1,” set the
snug point detection level to “L.”
Changing the snug point detection
level from “L1” to “L” may increase the
torque. Set the number of torque stages
again after making this change.
The setting will not be changed until
you press the OK button.
After changing the setting, be sure to check
the new setting value. (See page 7.)
IMPORTANT INFORMATION:
You can set the snug point detection
level and retightening prevention time at
the same time by changing the retight-
ening prevention time (See page )
before pressing the OK button and then
pressing the OK button.
Pressing the A button toggles the dis-
play between the snug point detection
level setting value and the number of
torque stages setting value.
The tool ships with the snug point
detection level set to “L1.”
When the number of torque stages has
been set as shown below, the snug
point detection level cannot be switched
from “L1” to “L.”
Model
Number of torque stages
setting
EYFPA
1 to 0
EYFNA
1 to 0
•
•
•
•
•
•
•
•
•