Replacement procedure
1) Turn off the Power and then remove the AC power plug from the wall outlet.
Wait at least 1 hour and make sure the lamp unit and surroundings are cool.
2) Use a Phillips screwdriver to loosen the Lamp cover screw (x1) and open the
lamp cover.
z
Open the lamp cover by pulling it slowly toward the direction of the arrow.
3) Use a Phillips screwdriver to loosen the lamp unit screws (x2) until the screws
turn freely. Pull up the handle, and pull it gently from the projector.
4) Insert the unused lamp unit in correct direction. Tighten the lamp unit screws
(x2) securely with a Phillips screwdriver.
5) Close the lamp cover, and tighten the lamp cover screw (x1) securely
with a
Phillips screwdriver.
6) Clean up the dust on the left and right air vents.
7)
Pull out the air filters straight and slowly with grabbing the knobs.
Lamp cover screw
Handle
Lamp unit screws
Lamp cover
Air filter (shorter filter with 3
rows of intake vents)
Air filter (longer filter with 5
rows of intake vents)
Protrusion
Protrusion
Knob