6 ATTACHING THE BACK CUSHION AND PILLOW

 

1

 Attach the back cushion using the zipper.

2

 Attach the pillow using the velcroes.

 BEFORE USING THE UNIT

1 CHECK THE SURROUNDING AREA

Check that there is nothing around the 

unit.

5 FIX THE CONTROLLER CORD

Approx. 0

 (51 cm) 

Use the controller cord velcroes to secure the cord, leaving approximately 20 in. 
(51 cm) of free wire.
*  Confirm that there is a margin for the controller cord length when the backrest is reclined.
(The illustration shows that the cord is attached to the right armrest.)

 FOLDING THE BACKREST FORWARD (REPACKING)

CAUTION

Keep hands, feet, children, objects, etc., clear of openings on the unit, including seat and armrests; gaps between 
the unit and the floor; and the backrest’s range of movement when being folded forward.
 
Failure to do so could result in injury.
The unit should not be turned on and the controls should not be operated on when the backrest is folded forward. 
Failure to follow these instructions could result in injury.
The unit should not be climbed on and objects should not be placed on the unit when the backrest is folded 
forward.

Failure to follow these instructions could result in damage to the unit.

In the interests of safety, the backrest should always be folded forward by two persons.

1

 Press the OFF/ON button to switch off the power.

2

 Slide the power switch to the “off” position, lock it, and then unplug the power 

cord.

3

 Remove the back cushion and the pillow from the unit.

4

 Remove the armrest from the unit.

Refer to “INSTALL THE ARMRESTS ON THE UNIT” on page 6 and remove them in 
reverse order.

5

 Insert a screwdriver into the opening for the backrest latch 

approx. 1.6 in. (4 cm) from the upper edge of the opening 

(until the screwdriver contacts the backrest latch).

6

 Push tip of screwdriver downward approx. 1 in. (2.5 cm) to 

release backrest latch.

7

 Pull out screwdriver when pushing of backrest toward 

seat begins.

*Be careful to avoid catching the controller or the cord between the backrest and the seat.
* It is recommended that you move the unit before folding the backrest (upright 

position). When the backrest is folded, it is not fixed and is unstable.

7

7

5

5

6

6

2 POWERING UP THE UNIT

 See Warning No. 7 on page 1.

1

 Make sure the power plug is functional.

Make sure the power plug is undamaged. Make sure the power plug is free of foreign matter and debris.

2

 Plug the power plug into an electrical outlet.

3

 Verify that the lock switch key is turned to the “open” position.

If in “lock” position, turn the lock switch key to “open”.

4

 Slide the power switch to the “on” position.

3 CHECK THE UNIT

1

3

1

 Make sure the chair covering is free of rips or 

tears.

2

 Make sure there are no obstacles between 

the parts of the unit.

3

 Make sure the massage heads are in the 

retracted position, i.e. they are parked to the 

left and right in the upper part of the backrest.

If not retracted, press 

 twice to return the massage heads to the 

retracted position.

 See Warning No. 14 on page .

4 ADJUSTING FOR CORRECT PILLOW HEIGHT

Velcroes

Adjust the pillow height so that the bottom edge 

of the pillow is at ear level. 

If positioned too low, the pillow can lessen the effect of massage around the 
neck area. 

5 ADJUSTING THE RECLINING ANGLE

Press reclining   to adjust the angle of the backrest.

With the button held down, movement will continue until a “beep-beep-beep” sound indicates the backrest has been raised or 
lowered as far as possible.

Approx. 120˚

Approx. 170˚

* The reclining operation is a function that adjusts the angle of the backrest. Avoid using it for any other purposes, such as 

continuous up/down operation etc.

   9-10

2007/12/12   19:14:43

Содержание EP1082KL-COMBO

Страница 1: ...N de Modelo N de mod le EP1082 Before operating this unit please read these instructions completely Antes de utilizar esta unidad lea compleatamente estas instrucciones y gu rdelas para referencia fu...

Страница 2: ...ug Return the unit to the nearest authorized service center if it is not working properly if it has been dropped or damaged or if it has been immersed in water 9 Keep power cords away from heated surf...

Страница 3: ...e than 5 minutes when first using it You can gradually increase the duration and strength of the massage as you become used to it Do not massage any one point for more than 5 minutes at a time Excessi...

Страница 4: ...d service center 6 Do not repeatedly operate any switch at short intervals Such action may cause the switch to malfunction 7 Some noise may be heard coming from the massager while in use This is due t...

Страница 5: ...nnection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded...

Страница 6: ...9 Handle 10 Back Cover 11 Backrest Latch 12 Safety Precaution Label SPECIFICATIONS Power Supply AC 120 V 60 Hz Power Consumption 160 W Upper Body Massage Massage Area Up Down Approx 26 6 in 67 5 cm M...

Страница 7: ...button Adjusts position of massage heads during manual operation See Page 13 21 OFF ON button Switches the controller on and off 22 Time Indicator Displays time remaining before end of massage 23 Pre...

Страница 8: ...AUTION When raising the backrest be careful not to cause hands or feet to become caught between the backrest and the backrest latch or the backrest and the armrests Failure to follow this precaution m...

Страница 9: ...hows the left armrest The right armrest is stamped Front Right and Back The left armrest must be installed on the left hand side of the unit 4 Align the proper armrest with the unit and connect Be car...

Страница 10: ...d result in injury The unit should not be climbed on and objects should not be placed on the unit when the backrest is folded forward Failure to follow these instructions could result in damage to the...

Страница 11: ...on i e they are parked to the left and right in the upper part of the backrest If not retracted press twice to return the massage heads to the retracted position See Warning No 14 on page 2 4 ADJUSTIN...

Страница 12: ...press another Pre Program button or a manual operation button during your selected pre program massage the massage will switch to the newly selected massage Pressing a Pre Program button automatically...

Страница 13: ...will also be massaged slightly Press the button again to toggle it off BRemoving tapping from pre programs Press Press the button again to restore tapping to the program 6 Auto shut off in pre program...

Страница 14: ...continue using the unit please press the OFF ON button Please rest at least 10 minutes between massages Massage Actions Knead Feels like the fingers and thumbs of two hands squeezing in unison as the...

Страница 15: ...elected E g 2 Adding Full Roll to the selection E g 3 Deselecting Full Roll Changing Massage Types E g 1 Changing massage types in the same category Changing to Hawaiian when Knead is selected E g 2 C...

Страница 16: ...T use a hair dryer to try to dry the surfaces more quickly Wearing of denim colored patterned or other clothing with a tendency to fade should be avoided during use as it could lead to discoloration o...

Страница 17: ...ent An alternating tapping method is employed which means that this phenomenon will naturally occur There is nothing wrong with the unit It is not possible to recline the unit If the unit encounters a...

Страница 18: ...mprim en Chine Panasonic Consumer Electronics Company One Panasonic Way 1H 1 Secaucus New Jersey 07094 1 800 338 0552 for questions and comments www panasonic com massage Panasonic Canada Inc 5770 Amb...

Отзывы: