ADJUSTMENT PROCEDURES
MCUK011201C8
Section 7
Issue B
Service Manual
– 41 –
Revision 0
2.
Automatic calibration only:
a)
Click on the READ_Hi button to check the BAT VOLT HIGH reading.
b)
Set the value using the ‘spinners’ (
arrows) or type in the value directly.
c)
Click on the APPLY button to set the BAT VOLT HIGH value.
d)
Repeat steps a) t o c), clicking the READ_LO button to check the BAT VOLT LOW reading.
Check the ADIN1 reading again - this is the BAT VOLT LOW value. If the reading is outside the range 389 -
489, there is a fault and further investigation is required. Otherwise, record this value for use later.