CUSTOM MODE
When MODE indicator: CUST (yellow) lights up, response
time setting, data bank loading (only one unit), or code set-
ting can be displayed. Setting contents of the displayed item
can be changed. For the setting procedure, refer to
<PRO
5: CUSTOM setting>
in “
14
PRO MODE
.”
For setting of each item, refer to the following table.
Jog switch
Press: Confirm setting
contents
Turn: Select setting
items
Item
Display display
Reference item
Response time setting
<PRO 1: Response time setting>
Data bank loading (Only
one unit)
<PRO 3: Data bank loading>
Code setting
<PRO 5: Code setting>
14
PRO MODE
When MODE indicator: PRO (yellow) lights up, PRO mode can be set.
The mode will change to RUN mode when the MODE key is held down during this
setting process. However, changed items before holding down the mode selection
key have been set.
Jog switch
;=
Turn: Select setting items
MODE key
Cancel during setting
Symbol explanation
Press : Press down the jog switch
Turn : Turn the jog switch
Automatic : Automatically move to next
PRO mode
PRO 1
PRO 2
PRO 3
PRO 4
PRO 5
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Press
Response
time setting
Digital dis-
play setting
Data bank
loading
Copy setting
Code setting
Reset setting
Data bank
saving
Communication en-
able / disable setting
Communication
protocol setting
CUSTOM
setting
Time period
hold setting
Display
adjustment
Eco setting
Hysteresis
setting
1ms
Lock OFF
1 unit only
YES
(2 cycles)
1 unit only
Communica-
tion enable
Communica-
tion mode
Response
time setting
All units
All units
1ch
1ch
1ch
1ch
YES
YES
good
good
good
Hold OFF
Display ad-
justment OFF
Eco OFF
Standard
Turn
Turn
Turn
Turn
Turn
Automatic
Automatic
Automatic
Automatic
Turn
Turn
Press
Press
Turn
Turn
Turn
Turn
Turn
Automatic
Turn
Turn
Turn
Turn
Jog switch
;=
Turn: Select code, shift decimal point
RUN mode
PRO 1
Item
Default setting
Description
PRO 1
Response time
setting
Sets response time.
“
>=?@QX*[
>=@QQX*[
”: 1ms, “
”: 5ms
“
”: 10ms, “
”: 50ms, “
”: 100ms, “
”: 500ms
Hysteresis setting
Hysteresis can be set when EASY mode or window comparator mode is set.
“
”: Small
“
”: Standard
“
”: Large
PRO 2
Digital display
setting
When setting to “
” (lock OFF) and pressing the jog switch in
RUN mode, pressure value and peak / bottom value can be switched to
show on the digital display (red).
“
”: Lock OFF
“
”: Lock ON
Eco setting
Power consumption can be lowered.
“
”: Eco OFF
“
”: Eco ON
If any key operation is not carried out for 20 sec. in RUN mode,
the digital display turns OFF.
“
”: Manual
The digital display turns OFF when setting the key lock function
to ON in RUN mode.
“
”: FULL
The digital display turns OFF if any key operation is not carried
out for 20 sec. or the key lock function is set to ON in RUN mode.
Time period hold
setting
“
”: Hold OFF
Peak / bottom value in the digital display refreshing condition
can be displayed.
“
”: Hold ON
Peak / bottom value in the hold condition can be displayed.
Display adjustment
Forcibly sets the pressure value indicated on the digital display to “zero.”
Threshold value changes in conjunction with the pressure value.
“
”: Display adjustment OFF
“
”: Display adjustment ON
PRO 3
Data bank loading
\ 6
“
”: Select this mode when only one unit to load.
“
”: Select this mode when all units to load in a lump by optical com-
munications. For optical communications, refer to “
16
OPTICAL
COMMUNICATIONS
.”
“
”: 1ch
“
”: 2ch
“
”: 3ch
Data bank saving
] 6
“
”: Select this mode when only one unit to save.
“
”: Select this mode when all units to save in a lump by optical com-
munications. For optical communications, refer to “
16
OPTICAL
COMMUNICATIONS
.”
“
”: 1ch
“
”: 2ch
“
”: 3ch
PRO 4
Copy setting
-
The set contents can be copied to all sub controllers cascaded to the right
side from the connector side of the main controller by optical communica-
tion. However, the data bank loading / saving, and zero-adjustment set-
tings are excluded.
For optical communications, refer to “
16
OPTICAL COMMUNICATIONS
.”
Communication en-
able / disable setting
When conducting the copy setting or data bank loading / saving from the main con-
troller via optical communications, it is possible that only the sub controller which is
set to communication disable “
”, not to receive the set contents.
“
”: Communication enable
“
”: Communication disable
Communication
protocol setting
When conducting the copy setting or data bank loading / saving from the main
controller via optical communications, it is possible that only the sub controller
which is set to communication halt “
”, not to receive the set contents.
“
”: Communication mode
“
”: Communication halt
PRO 5
Code setting
Consistent setting can be done by inputting 8-digit code instead of inde-
*
Reset setting
-
If setting to “
”, returns to default settings (factory settings).
CUSTOM setting
Selects an item in CUSTOM mode to display.
“
”: Response time setting
“
”: Data bank loading
“
”: Code setting
Code setting table
Code
4th digit
3rd digit
2nd digit
1st digit
NO / NC mode
Response time setting
Digital display
Digital display setting
Eco setting
NO / NO
?@QX
Pressure value
Lock OFF
Eco OFF
NC / NO
@QQX
Peak / bottom value
Eco ON
NO / NC
1ms
Pressure value
Lock ON
Manual
NC / NC
5ms
Peak / bottom value
FULL
-
10ms
-
-
-
-
50ms
-
-
-
-
100ms
-
-
-
-
500ms
-
-
-
-
-
-
-
-
Code
4th digit
3rd digit
2nd digit
1st digit
Communication
protocol setting
Communication en-
able / disable setting
CUSTOM mode
Comparative
output 1 mode
Hysteresis setting
Comparative
output 2 mode
Communication
mode
Communication
enable
Response time
setting
EASY mode
H-01
EASY mode
Communication
halt
Data bank loading
H-02
Hysteresis mode
Communication
mode
Communication
disable
Code setting
H-03
Forced ON output
mode
Communication
halt
-
Window comparator
mode
H-01
Forced OFF output
mode
-
-
-
H-02
-
-
-
-
H-03
-
-
-
-
Hysteresis mode
-
-
-
-
-
Forced ON output
mode
-
-
-
-
-
Forced OFF output
mode
-
-