INSTRUCTION MANUAL
Head Separated Digital Pressure Sensor Controller
DPS-400 Sreies
MJE-DPS400 No.0027-91V
Thank you very much for purchasing Panasonic products. Please read this Instruc-
tion Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
Never use this product in a device for personnel protection.
In case of using devices for personnel protection, use products which meet laws and standards,
such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
1
PART DESCRIPTION
MODE indicator: RUN (Green)
MODE indicator: OUT (Yellow)
MODE indicator: ZERO (Yellow)
Decimal point
mark (Note 1, 2)
MODE indicator: CUSTOM (Yellow)
MODE indicator: NO / NC (Yellow)
Digital display (Green / Red)
MODE indicator: PRO (Yellow)
Pressure unit (Note 1)
Comparative output 1 op-
eration indicator (Orange)
Comparative output 2 op-
eration indicator (Orange)
Select 1 indicator (Yellow)
Select 2 indicator (Yellow)
Jog switch
Press: Threshold value setting
Turn: Threshold value setting
Select setting items
MODE key
Select Modes
Cancel during setting
Notes: 1)
DPS-401
. Positions of the decimal
point mark and the pressure unit on the name plate for positive pressure type
DPS-402
2) The decimal point is used in RUN mode, threshold value setting mode, or peak / bottom hold function. It is
not used in other modes.
2
MOUNTING
How to mount
1.
Fit the rear part of the mounting section of the
controller on a DIN rail.
2.
Press down the rear part of the mounting section
the mounting section to the DIN rail.
2.
Press down
1.
Fit
35mm width DIN rail
How to remove
1.
Push the controller forward.
2.
Lift up the front part of the controller to remove it.
2.
Lift up
1.
Push forward
Note: Take care that if the front part is lifted without pushing the controller forward, the hook on the rear portion of the
mounting section is likely to break.
3
CONNECTION OF PRESSURE SENSOR HEAD
Make sure that the power supply is OFF while connecting or removing the pres-
sure sensor head
DPH-100
series (optional).
This product can automatically recognize the connected pressure sensor head.
When the pressure sensor head is replaced, the threshold value and the zero-
adjustment value change. Therefore, set those values again.
How to connect
Insert the connector of the pressure sensor head
DPH-100
series (optional) into the connector area
for the pressure sensor head of this product.
Connector area for the
pressure sensor head
Connector of the pressure
sensor head
DPH-100
series (Optional)
How to disconnect
Pressing the release lever attached to the connec-
tor of the pressure sensor head, pull out the con-
nector.
Release lever
Note: Do not pull by holding the cable without pressing the release lever, as this can cause cable break or connector break.
<Terminal arrangement>
1
2
3
4
Terminal No.
Terminal name
1
Pressure sensor head power supply
2
Analogue input
3
0V
4
Model discrimination signal
4
CONTROLLER CASCADING
Make sure that the power supply is OFF while adding or removing the series
connection type.
In case 2 or more the series connection types are connected in cascade, make
sure to mount them on a DIN rail.
The maximum 11 the controllers using sub cables
CN-72-C
! "#
added to a controller using a main cable
CN-74-C
!"#
When connecting 2 or more in cascade, use the sub cable for the second series
connection type onwards.
For mounting and removing the controller, refer to “
2
MOUNTING
.”
How to cascade
1.
Mount the controllers, one by one, on the
DIN rail.
2.
Slide the controllers next to each other,
and connect the quick-connection ca-
bles.
3.
Mount the end plates
MS-DIN-E
(option-
al) at both the ends to hold the control-
$
4.
%
Communication window
Slide
Sub cable
CN-72-C
!"&#
Main cable
CN-74-C
!"&#
End plate
MS-DIN-E
(Optional)
End plate
MS-DIN-E
(Optional)
How to remove
1.
Loosen the screws of the end plates.
2.
Remove the end plates.
3.
Slide the controllers and remove them
one by one.
Slide
5
I/O CIRCUIT DIAGRAM
Main circuit
(Brown) +V (Note)
(Black) Comparative output 1
(White) Comparative output 2
(Blue) 0V (Note)
Load
Load
+
12 to 24V DC
±10%
-
Note: The quick-connection sub cable does not have +V (brown) and 0V (blue). The power is supplied from the con-
nector of the main cable.
<Terminal arrangement>
1
2
3
4
Terminal No.
Terminal name
1
+V
2
Comparative output 1
3
0V
4
Comparative output 2
6
COMPARATIVE OUTPUT CHANNEL SWITCHING
Press the MODE key for 2 sec. or more to switch the
comparative output 1 / 2.
Comparative output 1 can be set when the Select 1 in-
dicator (yellow) lights up, and the comparative output 2
can be set when the Select 2 indicator (yellow) lights up.
Select 2 indi-
cator (Yellow)
Select 1 indi-
cator (Yellow)
7
OUTPUT MODE AND OUTPUT OPERATION
The EASY mode, window comparator mode, hysteresis mode, forced ON output
mode, or forced OFF output mode can be selected individually as the comparative
output mode 1 or the comparative output 2.
However, the comparative output 2 cannot be set to the window comparator
mode.
For details, refer to “
12
OUTPUT MODE
.”
EASY mode
The comparative output ON / OFF state can be controlled in this mode.
Pressure
SL
0
ON
OFF
Comparative
output
H (Hysteresis)
H: Hysteresis (Note)
In case of compound pressure type or positive pres-
sure type, hysteresis is set to the lower pressure side.
In case of vacuum pressure type, hyster-
esis is set to the lower vacuum side.
Note: Hysteresis can be set to “
” (1% F.S.), “
” (2% F.S.) or “
” (5% F.S.).
For setting method, refer to
<PRO 1: Hysteresis setting>
in “
14
PRO MODE
.”
Window comparator mode
In this mode, the ON or OFF state of the comparative output is controlled with a
pressure in the set range.
H: Hysteresis (Note 1)
In case of compound pressure type or positive pres-
sure type, hysteresis is set to the lower pressure side.
In case of vacuum pressure type, hyster-
esis is set to the lower vacuum side.
Pressure
Comparative
output
2_SL
1_SL
0
ON
OFF
H (Hysteresis)
H (Hysteresis)
Notes: 1) Hysteresis can be set to “
” (1% F.S.), “
” (2% F.S.) or “
” (5% F.S.).
For setting method, refer to
<PRO 1: Hysteresis setting>
in “
14
PRO MODE
.”
2) Window comparator mode cannot be used as the comparative output 2.
For details, refer to “
12
OUTPUT MODE
.”