Panasonic DPS-400 Series Скачать руководство пользователя страница 1

INSTRUCTION MANUAL

Head Separated Digital Pressure Sensor Controller

DPS-400 Sreies

MJE-DPS400 No.0027-91V

Thank you very much for purchasing Panasonic products. Please read this Instruc-
tion Manual carefully and thoroughly for the correct and optimum use of this product. 
Kindly keep this manual in a convenient place for quick reference.

WARNING

 

 Never use this product in a device for personnel protection.

 

 In case of using devices for personnel protection, use products which meet laws and standards, 

such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.

1

PART DESCRIPTION

MODE indicator: RUN (Green)

MODE indicator: OUT (Yellow)

MODE indicator: ZERO (Yellow)

Decimal point 
mark (Note 1, 2)

MODE indicator: CUSTOM (Yellow)

MODE indicator: NO / NC (Yellow)

Digital display (Green / Red)

MODE indicator: PRO (Yellow)

Pressure unit (Note 1)

Comparative output 1 op-
eration indicator (Orange)

Comparative output 2 op-
eration indicator (Orange)

Select 1 indicator (Yellow)

Select 2 indicator (Yellow)

Jog switch

Press: Threshold value setting

 

Turn:  Threshold value setting
 

Select setting items

MODE key

Select Modes
Cancel during setting

Notes: 1)    

DPS-401

. Positions of the decimal 

point mark and the pressure unit on the name plate for positive pressure type 

DPS-402

 

 

2) The decimal point is used in RUN mode, threshold value setting mode, or peak / bottom hold function. It is 

not used in other modes.

2

MOUNTING

How to mount

1. 

Fit the rear part of the mounting section of the 
controller on a DIN rail.

2. 

Press down the rear part of the mounting section 

the mounting section to the DIN rail.

2. 

Press down

1. 

Fit

35mm width DIN rail

How to remove

1. 

Push the controller forward.

2. 

Lift up the front part of the controller to remove it.

2. 

Lift up

1. 

Push forward

Note:  Take care that if the front part is lifted without pushing the controller forward, the hook on the rear portion of the 

mounting section is likely to break.

3

CONNECTION OF PRESSURE SENSOR HEAD

 

 Make sure that the power supply is OFF while connecting or removing the pres-

sure sensor head 

DPH-100

 series (optional).

 

 This product can automatically recognize the connected pressure sensor head.

 

 When the pressure sensor head is replaced, the threshold value and the zero-

adjustment value change. Therefore, set those values again.

How to connect

 

 Insert the connector of the pressure sensor head 

DPH-100

 series (optional) into the connector area 

for the pressure sensor head of this product.

Connector area for the 
pressure sensor head

Connector of the pressure 
sensor head 

DPH-100

 series (Optional)

How to disconnect

 

 Pressing the release lever attached to the connec-

tor of the pressure sensor head, pull out the con-
nector.

Release lever

Note:  Do not pull by holding the cable without pressing the release lever, as this can cause cable break or connector break.

<Terminal arrangement>

1
2

3
4

Terminal No.

Terminal name

1

Pressure sensor head power supply

2

Analogue input

3

0V

4

Model discrimination signal

4

CONTROLLER CASCADING

 

 Make sure that the power supply is OFF while adding or removing the series 

connection type.

 

 In case 2 or more the series connection types are connected in cascade, make 

sure to mount them on a DIN rail.

 

 The maximum 11 the controllers using sub cables 

CN-72-C

! "#  

added to a controller using a main cable 

CN-74-C

!"#

 

 When connecting 2 or more in cascade, use the sub cable for the second series 

connection type onwards.

For mounting and removing the controller, refer to “

2

MOUNTING

.”

How to cascade

1. 

Mount the controllers, one by one, on the 
DIN rail.

2. 

Slide the controllers next to each other, 
and connect the quick-connection ca-
bles.

3. 

Mount the end plates 

MS-DIN-E

 (option-

al) at both the ends to hold the control-
$

4. 

%

Communication window

Slide

Sub cable

CN-72-C

!"&#

Main cable

CN-74-C

!"&#

End plate

MS-DIN-E

 (Optional)

End plate

MS-DIN-E

 (Optional)

How to remove

1. 

Loosen the screws of the end plates.

2. 

Remove the end plates.

3. 

Slide the controllers and remove them 
one by one.

Slide

5

I/O CIRCUIT DIAGRAM

Main circuit

(Brown) +V (Note)

(Black) Comparative output 1

(White) Comparative output 2

(Blue) 0V (Note)

Load

Load

+

12 to 24V DC
±10%

-

Note: The quick-connection sub cable does not have +V (brown) and 0V (blue). The power is supplied from the con-

nector of the main cable.

<Terminal arrangement>

1
2
3

4

Terminal No.

Terminal name

1

+V

2

Comparative output 1

3

0V

4

Comparative output 2

6

COMPARATIVE OUTPUT CHANNEL SWITCHING

 

 Press the MODE key for 2 sec. or more to switch the 

comparative output 1 / 2.

 

 Comparative output 1 can be set when the Select 1 in-

dicator (yellow) lights up, and the comparative output 2 
can be set when the Select 2 indicator (yellow) lights up.

Select 2 indi-
cator (Yellow)

Select 1 indi-
cator (Yellow)

7

OUTPUT MODE AND OUTPUT OPERATION

 

 The EASY mode, window comparator mode, hysteresis mode, forced ON output 

mode, or forced OFF output mode can be selected individually as the comparative 
output mode 1 or the comparative output 2. 
However, the comparative output 2 cannot be set to the window comparator 
mode.
For details, refer to “

12

OUTPUT MODE

.”

EASY mode

 

 The comparative output ON / OFF state can be controlled in this mode.

Pressure

SL

0

ON

OFF

Comparative 
output

H (Hysteresis)

H: Hysteresis (Note)

In case of compound pressure type or positive pres-
sure type, hysteresis is set to the lower pressure side.
In case of vacuum pressure type, hyster-
esis is set to the lower vacuum side.

Note:  Hysteresis can be set to “ 

 ” (1% F.S.), “ 

 ” (2% F.S.) or “ 

 ” (5% F.S.).

 

For setting method, refer to 

<PRO 1: Hysteresis setting>

 in “

14

PRO MODE

.”

Window comparator mode

 

 In this mode, the ON or OFF state of the comparative output is controlled with a 

pressure in the set range.

H: Hysteresis (Note 1)

In case of compound pressure type or positive pres-
sure type, hysteresis is set to the lower pressure side.
In case of vacuum pressure type, hyster-
esis is set to the lower vacuum side.

Pressure

Comparative 
output

2_SL

1_SL

0

ON

OFF

H (Hysteresis)

H (Hysteresis)

Notes: 1) Hysteresis can be set to “ 

 ” (1% F.S.), “ 

 ” (2% F.S.) or “ 

 ” (5% F.S.).

 

 

For setting method, refer to 

<PRO 1: Hysteresis setting>

 in “

14

PRO MODE

.”

 

2) Window comparator mode cannot be used as the comparative output 2.

 

 

For details, refer to “

12

OUTPUT MODE

.”

Содержание DPS-400 Series

Страница 1: ...tion signal 4 CONTROLLER CASCADING Make sure that the power supply is OFF while adding or removing the series connection type In case 2 or more the series connection types are connected in cascade make sure to mount them on a DIN rail The maximum 11 the controllers using sub cables CN 72 C added to a controller using a main cable CN 74 C When connecting 2 or more in cascade use the sub cable for t...

Страница 2: ...g mode are not inadvertently changed If operating the jog switch or MODE key after key lock is set is indi cated on the digital display Setting of key lock Press down for 3 sec or more Automatic Release of key lock Press down for 3 sec or more Automatic Peak bottom hold function 6 6 Set the digital display to lock OFF while pressure value is indi cated on the digital display red After setting pres...

Страница 3: ... to ON in RUN mode Time period hold setting Hold OFF Peak bottom value in the digital display refreshing condition can be displayed Hold ON Peak bottom value in the hold condition can be displayed Display adjustment Forcibly sets the pressure value indicated on the digital display to zero Threshold value changes in conjunction with the pressure value Display adjustment OFF Display adjustment ON PR...

Страница 4: ...ny of the following conditions the data bank loading saving or copy setting cannot be carried out In case the digital display is blinking In case PRO mode is being set In case the communication enable disable setting is set to communication dis able When communication protocol of a sub controller is set to communication halt the data bank loading saving or copy setting cannot be carried out to sub...