14
8.1.2.
Special Modes Setting
PLEASE
WAIT
Unit is in termination process
Unit is in termination process now.
“BYE” is displayed and power will be turned
off.
In case “Quick Start” of setup menu is ON, it
is displayed in restoration operation for AC
off.
No display
Item
FL display
Key operation
Mode name
Description
Front Key
TEST Mode
*All the main unit's parameters (include tuner)
are initialized.
Press [STOP], [CH UP] and [OPEN/
CLOSE] keys simultaneously for
five seconds when power is off.
Service Mode
Setting every kind of modes for servicing.
*Details are described in “
8.1.3. Service
Mode at a glance
”.
When the power is off, press [CH
UP], [OPEN/CLOSE] and [REC]
keys simultaneously for 5 seconds.
Forced disc eject
Removing a disc that cannot be ejected.
The tray will open and unit will shift to P-off
mode.
*When Timer REC is ON, execute " Forced
disc eject " after releasing Timer REC.
While Demonstration Lock is being set, this
Forced disc eject function is not accepted.
The display before execution
leaves.
When the power is off, press
[STOP] and [CH UP] keys simulta-
neously for 5 seconds.
Forced power-off
When the power button is not effective while
power is ON, turn off the power forcibly.
*When Timer REC is ON, execute “Forced
Power-off” after releasing Timer REC.
Display in P-off mode.
Press [Power] key over than 10 sec-
onds.
Aging
Perform sequence of modes as * Aging
Description shown below continually.
Display following the then mode.
When the power is ON, press
[STOP], [POWER] and [OPEN/
CLOSE] simultaneously for over 5
seconds and less than 10 seconds.
NOTE1:
If Unit has not turned into Aging
mode by operations shown above,
execute TEST MODE once and re-
execute operation shown above.
(*All the main unit’s parameters
include tuner are initialized by TEST
mode.)
NOTE2:
If the unit has hung-up because of
pressing keys for over 10 seconds,
once turn off the power, and re-exe-
cute this command.
*When releasing Aging mode, press
[POWER] key.
Aging Contents (Example):
Error Code
Diagnosis contents
Description
Monitor Display
Automatic FL display
Содержание DMR-ES20P
Страница 6: ...6 3 Service Navigation 3 1 Service Information 3 2 Flow chart for confirmation ...
Страница 9: ...9 4 Specifications ...
Страница 11: ...11 6 Location of Controls and Components ...
Страница 27: ...27 11 1 2 Checking and Repairing of Main P C B ...
Страница 28: ...28 11 1 3 Checking and Repairing of DVD RAM Drive ...
Страница 40: ...S 9 ...
Страница 67: ...S 36 ...
Страница 69: ...S 38 ...
Страница 70: ...S 39 ...
Страница 71: ...S 40 ...
Страница 72: ...S 41 ...
Страница 75: ...S7 2 Packing Parts Accessories Section S 44 A1 BATTERY REMOTE CONT A2 A3 A4 A1 1 A5 PC1 PC3 PC2 A9 A10 A6 A7 ...