1 Safety Precautions
1.1 General Guidelines
1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by in the Schematic Diagrams, Circuit Board
Layout, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced with manufacturer's specified parts to prevent
X-RADIATION, shock fire, or other hazards. Do not modify the original design without permission of manufacturer.
2. An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis is not isolated from the AC power line. Use a transformer
of adequate power rating as this protects the technician from accidents resulting in personal injury from electrical shocks. It will also protect AC Adaptor from
being damaged by accidental shorting that may occur during servicing.
3. When servicing, observe the original lead dress. It a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.
4. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed.
5. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.2 Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on the equipment such as
screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the chassis, the reading should be between 1MΩ and
5.2MΩ. When the exposed metal does not have a return path to the chassis, the reading must be infinity.
1.3 Leakage Current Hot Check (See Figure 1)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5kΩ, 10 W resistor, in parallel with a 0.15µF capacitor, between each exposed metallic part on the set and a good earth ground, as shown in
Figure 1
.
3. Use an AC voltmeter, with 1 kΩ/V or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 or equivalent) may be used to make the hot checks, leakage current must not exceed 1/2 mA. In case a
measurement is outside of the limits specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is
returned to the customer.
Figure 1
1.4 How to Discharge the Capacitor on Flash P.C.B.
CAUTION:
1.
Be sure to discharge the capacitor on Flash P.C.B.
2.
Be careful of the high voltage circuit on Flash P.C.B. when servicing.
Page 1 of 2
10/28/2017
file://\\royalfs\Service\Technical\Ms.dehghani\All SVC sent by CD\20\DMC-FT25EBAL...
Содержание DMC-FT25EB
Страница 15: ...Page 2 of 3 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 16: ...Page 3 of 3 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 24: ...Page 4 of 6 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 28: ...Page 2 of 3 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 44: ...Fig D12 Page 15 of 19 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 48: ...Fig D16 Page 19 of 19 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...
Страница 52: ...Page 4 of 6 10 28 2017 file royalfs Service Technical Ms dehghani All SVC sent by CD 20 DMC FT25EBAL ...